Product data template, per EN ISO 23387

Gas water heater

- V1.1

Active
Property Unit Description Reference document
Classification<System><Table>Code No unit

Classification<System><Table>code:
Classification code of the product, ex. ClassificationSecclassProductsNumber = Pr_20_85_08

n/a
Classification<System><Table>Title No unit

Classification<System><Table>title:
Classification title of the product, ex. ClassificationSecclassProductsDescription = Timber beams

n/a
Classification<System><Table>Version No unit

Classification<System><Table>version:
Classification system version used, ex. ClassificationSecclassProductsVersion = v1.4

n/a
Name IFC Logo Nome No unit

Name:
The product name shall consist of the following fields: <Source>_<Type>_<Subtype>_<Differentiator_n>, ex. LEDSMART_Luminaire_Interior_1420x37x84mm. For more information, consult the standard draft Building Information Modelling (BIM) - Rules for the Modelling of BIM Objects and the link: https://secclass.pt/wp-content/uploads/2021/10/R_M_ObjectosBIM.pdf

n/a
CommercialName No unit

Commercial name:
The commercial name of the product, which usually is used to define the product for costumers

n/a
ProductType No unit

Product type:
The type of the product

n/a
Description IFC Logo Descricao No unit

Description:
A general description of the object

n/a
EPDRegistrationNumber No unit

EPD registration number:
Registration number of the Environmental Project Declaration document

n/a
ReferenceToOriginalEPD IFC Logo ReferenciaDAP No unit

Reference to original EPD:
a hyperlink to the original EPD according to standard PCR

n/a
DOPReference No unit

DOP reference:
Reference of the Declaration of Performance

n/a
UrlDOP No unit

URL DOP:
A URL to the DoP document (PDF, or digital version)

n/a
Manufacturer IFC Logo Fabricante No unit

Manufacturer:
The organization that manufactured and/or assembled the item

n/a
ManufacturerURL No unit

Manufacturer URL:
The website of the organization that manufactured and/or assembled the item

n/a
ManufacturerEmail No unit

Manufacturer email:
The email of the manufacturer

n/a
ManufacturerNumber No unit

Manufacturer number:
The contact number of the manufacturer

n/a
ModelReference IFC Logo ReferenciaModelo No unit

Model reference:
The model number or designator of the product model (or product line) as assigned by the manufacturer of the manufactured item, ex. ASMD Metal Door

n/a
BarCode IFC Logo CodigoDeBarras No unit

Bar code:
The identity of the bar code given to an occurrence of the product

n/a
SerialNumber IFC Logo NumeroDeSerie No unit

Serial number:
The serial number assigned to an occurrence of a product

n/a
GlobalTradeItemNumber IFC Logo NumeroGlobalDeItemComercial No unit

Global trade item number (GTIN):
The Global Trade Item Number (GTIN) is an identifier for trade items developed by GS1 (www.gs1.org), ex. 123456789012

n/a
ProductionDate No unit

Production date:
The date of production of the manufactured item, ex. 31/12/1999 23:59:59

n/a
AcquisitionDate IFC Logo DataAquisicao No unit

Acquisition date:
The date that the manufactured item was purchased, ex. 31/12/1999 23:59:59

n/a
NetWeight IFC Logo PesoLiquido kg

Net weight:
Element net weight excluding shipping packaging, ex. 60 kg

n/a
GrossWeight IFC Logo PesoBruto kg

Gross weight:
Element weight including shipping packaging, ex. 55 kg

n/a
MaterialWeight No unit

Material weight:
Weight of the referenced material in the product. ex. WoodWeight = 20

n/a
<Material>Origin No unit

<Material> origin:
Origin of the referenced material ex. WoodOrigin = Portugal

n/a
<Material>DPPurl No unit

<Material> DPP Url:
The URL that leads to the Digital Product Passport of the selected material

n/a
Packaging<Material>Weight No unit

Packaging <material> weight:
The weight of the packaging material referenced

n/a
ConceptualCost No unit

Conceptual cost:
Conceptual cost estimating is done during the pre-construction stage of a project, ex. 200 EUR

n/a
RecordedActualCost No unit

Recorded actual cost:
the actual cost of the asset , ex. 195EUR

n/a
ReplacementCost No unit

Replacement cost:
An indicative cost for unit replacement, ex. 200 EUR

n/a
FutureCostAssumptions No unit

Future cost assumptions:
Costs estimates for maintaining the element during its lifecycle, ex. 50EUR

n/a
ShippingCost No unit

Shipping cost:
Cost of shipping to installation location

n/a
Constituents No unit

Constituents:
Optional constituent features, parts or finishes, ex. Door with self closing lock

n/a
Color IFC Logo Cor No unit

Color:
Color selection for this object, ex. White, Brown, and Black

n/a
Category No unit

Category:
Category of the product when similar products exist belonging to the same product type. For example ceramic tiles have several categories that can be used in different context. Ex: Floor tile, Skirting, Wall tile, …

n/a
Finish IFC Logo Acabamento No unit

Finish:
Characteristic or primary finish of product

n/a
Features No unit

Features:
Other important characteristics or features relevant to product specification.

n/a
Material No unit

Material:
Characteristic or primary material of product., ex. Pine wood

n/a
FacilityIdentifier No unit

Facility identifier:
A unique identifier assigned to a physical location, such as a manufacturing plant, warehouse, or other facility, where specific activities related to a product occur. It is used to trace operations, ensure compliance, and maintain supply chain transparency.

n/a
EconomicOperatorIdentifier No unit

Economic operator identifier:
A unique identifier assigned to an entity responsible for the product at specific stages of its lifecycle, such as manufacturing, importing, or distribution. It ensures regulatory compliance, accountability, and traceability in the supply chain.

n/a
ManufacturerGLN No unit

Manufacturer GLN:
GLN- Global Location Number of the Manufacturer. This could be your local or headquarter GLN depending on point of origin, ex. 1234567890123

n/a
DataDeliveryCountry No unit

Data delivery country:
Country for which data delivery is planned. Territory (i.e. country, state, region) coded according to ISO 3166-1 Alpha2, ex. FR

n/a
DataDeliveryLanguage No unit

Data delivery language:
Basic language of the data delivery. This element specifies the used languages (acc. ISO 639-1), especially the default language of all language-dependent information, ex. fr

n/a
StartOfValidity No unit

Start of validity:
The start date of validity of the article, ex. 31/12/1999

n/a
EndOfValidity No unit

End of validity:
The end date of validity of the article, ex. 31/12/1999

n/a
<Attachment>Url No unit

<Attachment> Url:
URL to the referenced attachment/digital asset ex. ProductPhotourl = www.manufcaturer.com/product/photo

n/a
DeepLinkUrl No unit

Deep link URL:
A deep link (URL) redirects to a relevant webpage of the supplier or manufacturer company, where further information on the article may be found, ex. www.company.com/product

n/a
CountryOfOrigin No unit

Country of origin:
Country of origin is the country where the article was manufactured, or the last essential processing step was completed. Description of the country according to >>ISO-3166-1 Alpha2<< (Country Subdivision Codes). Country codes must be written in 2 capital letters, ex. PT

n/a
LocationOfOrigin No unit

Location of origin:
The location where the product was manufactured, can be the city or an address

n/a
ProductionProcessSummary No unit

Production process summary:
Stages of production

n/a
TransportType No unit

Transport type:
The type of transport used to distribute the product

n/a
PackagingType No unit

Packaging type:
The type of packaging used for the product

n/a
PressureRating No unit

Pressure rating:
Nominal pressure rating of the boiler as rated by ASME Boiler and Pressure Vessel Code Section IV, Rules for Construction of Heating Boilers, and Section I, Rules for Construction of Power Boilers

n/a
NominalPartLoadRatio %

Nominal part load ratio:
Allowable part load ratio range

n/a
WaterInletTemperatureRange °C

Water inlet temperature range:
Allowable water inlet temperature range

n/a
PartialLoadEfficiencyCurves %

Partial load efficiency curves:
Boiler efficiency as a function of the partial load factor; E = f (partialLoadfactor)

n/a
NominalEfficiency %

Nominal efficiency:
The nominal efficiency of the boiler as defined by the manufacturer. For water boilers, a function of inlet versus outlet temperature. For steam boilers, a function of inlet temperature versus steam pressure

EN ISO 15502-1:2012+A1:2015

HeatOutput kW

Heat output:
Total nominal heat output as listed by the Boiler manufacturer. For water boilers, it is a function of inlet versus outlet temperature. For steam boilers, it is a function of inlet temperature versus steam pressure

EN ISO 15502-1:2012+A1:2015

OutletTemperatureRange °C

Outlet temperature range:
Allowable outlet temperature of either the water or the steam

n/a
NominalEnergyConsumption W

Nominal energy consumption:
Nominal fuel consumption rate required to produce the total boiler heat output

n/a
UsefulEfficiencyPartLoad %

Useful efficiency part load:
The useful efficiency for a load corresponding to 30 % of the nominal heat input or for range rated boilers to 30 % of the arithmetic mean of the maximum and minimum heat input, expressed in percent

EN ISO 15502-1:2012+A1:2015

StandbyLosses %

Standby losses:
Heat losses in standby mode

EN ISO 15502-1:2012+A1:2015

NominalHeatInput kW

Nominal heat input:
Value of the heat input declared by the manufacturer

EN ISO 15502-1:2012+A1:2015

NominalDomesticHotWaterHeatInput kW

Nominal domestic hot water heat input:
Value of the heat input in the domestic hot water mode indicated by the manufacturer

EN ISO 15502-1:2012+A1:2015

NominalCondensingOutput kW

Nominal condensing output:
Useful output declared by the manufacturer in kW, corresponding to the operation of the boiler in a condensing (like 50 °C/30 °C) water temperature regime

EN ISO 15502-1:2012+A1:2015

HeatingUpTimeDomesticHotWater min

Heating up time domestic hot water:
Domestic hot water heating time

EN ISO 15502-1:2012+A1:2015

NominalVoltage Volt

Nominal voltage:
Voltage or range of voltages stated by the manufacturer at which the boiler can operate normally

EN ISO 15502-1:2012+A1:2015

GasSupplyPressure mbar

Gas supply pressure:
The gas supply pressure in millibars, if several normal pressures can be used for the same gas group. They are indicated by their numerical value and the unit “mbar”

EN ISO 437:2003+A1:2009

MinimumPressure bar

Minimum pressure:
The minimum pressure at the inlet to the domestic water circuit

EN ISO 437:2003+A1:2009

MaximumWaterSideOperatingPressureHeatingWater bar

Maximum water side operating pressure heating water:
The maximum water pressure at which the boiler can be used, in bars given by the symbol “PMS”, followed by the equals sign, the numerical value and the unit “bar"

EN ISO 437:2003+A1:2009

MaximumWaterServicePressureSanitaryWater bar

Maximum water service pressure sanitary water:
Maximum water service pressure for combination boilers for the domestic water circuit (PMW), in bar

EN ISO 437:2003+A1:2009

RatedPowerInput W

Rated power input:
The rated power input in Watts given by the numerical value followed by the unit “W”

EN ISO 60335-1-2012 + A11-2014

MaximumWaterTemperature °C

Maximum water temperature:
Information about the maximum water temperature in °C

EN ISO 15502-1:2012+A1:2015

NOxClass No unit

NOx class:
The NOx (nitrogen oxides) class of the boiler. Ex.: Class 1, 2, 3, 4, 5

EN ISO 15502-1:2012+A1:2015

WeightingNOx No unit

Weighting NOx:
The NOx Concentration in mg/kWh

EN ISO 15502-1:2012+A1:2015

AuxiliaryElectricityConsumptionAtNominalHeatInput kW

Auxiliary electricity consumption at nominal heat input:
The auxiliary electricity consumption in kiloWatt

EN ISO 15502-1:2012+A1:2015

AuxiliaryElectricityAtPartLoad kW

Auxiliary electricity at part load:
The auxiliary electricity consumption kW for a load corresponding to 30 % of the nominal heat input in kiloWatt

EN ISO 15502-1:2012+A1:2015

AuxiliaryElectricityAtStandby kW

Auxiliary electricity at standby:
During the measurement in stand-by the demand of auxiliary energy per hour, expressed in kiloWatt

EN ISO 15502-1:2012+A1:2015

IgnitionRate kW

Ignition rate:
Average heat input during the ignition safety time

EN ISO 15502-1:2012+A1:2015

COConcentration %

CO concentration:
The CO concentration in the dry, air-free, products of combustion

EN ISO 15502-1:2012+A1:2015

SoundPowerLevel dB

Sound power level:
The sound power level of the gas boiler in dB

EN ISO 15036-1:2006

Model No unit

Model:
Information identifying the model(s) to which the information relates

EN ISO 15502-1:2012+A1:2015

IsCombinationBoiler No unit

Is combination boiler:
Indication whether the boiler is designed both for central heating and for the production of domestic hot water (TRUE) or not (FALSE)

EN ISO 15502-1:2012+A1:2015

IsCondensingBoiler No unit

Is condensing boiler:
For Boiler in which, under normal operating conditions and at certain operating water temperatures, indication whether the water vapour in the combustion products is partially condensed, in order to make use of the latent heat of this water vapour for heating purposes (TRUE) or not (FALSE)

EN ISO 15502-1:2012+A1:2015

IsLowTemperatureBoiler No unit

Is low temperature boiler:
Indication whether the boiler which can work continuously with a water supply temperature of 35 °C to 40 °C, producing condensation in certain circumstances (TRUE) or not (FALSE)

EN ISO 15502-1:2012+A1:2015

GasCategory No unit

Gas category:
Gases are classified into families, groups and ranges in accordance with EN 437

EN ISO 437:2003+A1:2009

BoilerClass No unit

Boiler class:
Boilers are classified into categories in accordance with EN 437

EN ISO 437:2003+A1:2009

WeldJointType No unit

Weld joint type:
Type of weld joint. Ex. Square butt weld, square butt weld (double), single-V butt weld

ISO EN 2553:1992

ConnectionGasPipe No unit

Connection gas pipe:
Type of gas pipe connection. If the boiler has no flanges, pipe connection shall comply with EN ISO 228-1, EN 10226-1, EN 10226-2, or EN 1057. In the first case (EN ISO 228-1), the end of the boiler inlet connection shall offer a sufficiently flat annular surface to allow the use of a sealing washer. If flanges are used, they shall comply with EN 1092 and the manufacturer shall provide the counter-flanges and sealing gaskets

EN ISO 228-1

ConnectionCentralHeatingCircuit No unit

Connection central heating circuit:
Type of central heating circuit connection. Threaded connections shall comply with EN ISO 228-1, EN 10226-1 or EN 10226-2. If copper connections are used, the connecting end of the tube shall comply with EN 1057. If other than metallic materials are used, the manufacturer shall provide the appropriate justification for their suitability of use

EN ISO 228-1

DomesticWaterConnection No unit

Domestic water connection:
Type of domestic water connection. Threaded connections shall comply with EN ISO 228-1, EN 10226-1 or EN 10226-2. If copper tubes are used for the connection, the end of the tube shall comply with EN 1057

EN ISO 228-1

SurfaceProtectionOfTank No unit

Surface protection of tank:
Type of surface protection of the boiler tank. Ex.: Untreated, coated, enamelled, other

n/a
MaterialCasing No unit

Material casing:
Type of material casing. Ex.: None, plastic, stainless steel, steel, wood, other

n/a
HeatupTimeFrom10CelsiusDegreeTo65CelsiusDegree min

Heatup time from10 celsius degree to65 celsius degree:
Heat-up time to raise temperature from 10°C to 65°C in minutes

n/a
HotTapWaterCapacityAt40CelsiusDegree l/min

Hot tap water capacity at40 celsius degree:
Continuous hot water output capacity from the tap at 40°C in liters per minute

n/a
SuitableForLowCalorificNaturalGas No unit

Suitable for low calorific natural gas:
It the boiler allows the use of low-calorific gas. Ex.: Standard, automatic, manual, by means of conversion kit included, by means of conversion kit not included, not suitable

n/a
SuitableForHighCalorificNaturalGas No unit

Suitable for high calorific natural gas:
It the boiler allows the use of high-calorific gas. Ex.: Standard, automatic, manual, by means of conversion kit included, by means of conversion kit not included, not suitable

n/a
SuitableForPropane No unit

Suitable for propane:
It the boiler allows the use of propane. Ex.: Standard, automatic, manual, by means of conversion kit included, by means of conversion kit not included, not suitable

n/a
SuitableForButane No unit

Suitable for butane:
It the boiler allows the use of butane. Ex.: Standard, automatic, manual, by means of conversion kit included, by means of conversion kit not included, not suitable

n/a
SuitableForMethane No unit

Suitable for methane:
It the boiler allows the use of methane. Ex.: Standard, automatic, manual, by means of conversion kit included, by means of conversion kit not included, not suitable

n/a
SuitableForLiquifiedPetroleumGas No unit

Suitable for liquified petroleum gas:
It the boiler allows the use of liquefied petroleum gas (LPG). Ex.: Standard, automatic, manual, by means of conversion kit included, by means of conversion kit not included, not suitable

n/a
SuitableForHydrogen No unit

Suitable for hydrogen:
It the boiler allows the use of hydrogen. Ex.: Standard, automatic, manual, by means of conversion kit included, by means of conversion kit not included, not suitable

n/a
PercentageHydrogen %

Percentage hydrogen:
Percentage of hydrogen used by boilers in a mixture of hydrogen and natural gas

n/a
IsElectronicIgnition No unit

Is electronic ignition:
Whether the boiler has an electronic ignition device which only ignite the gas supply when the thermostat is on (TRUE) or not (FALSE)

n/a
IsPilotLightBurner No unit

Is pilot light burner:
Whether the boiler has the flame (pilot light) that light the gas provided by the main burner (TRUE) or not (FALSE). A small amount of gas is constantly released from the gas pipe, meaning that the flame lights the gas and it permanently burns

n/a
IsWallSetup No unit

Is wall setup:
Whether the boiler is desingned to be installed on the wall (TRUE) or not (FALSE)

n/a
IsVerticalPositioning No unit

Is vertical positioning:
Whether the boiler is vertical oriented (TRUE) or not (FALSE)

n/a
WithDrainPossibilityConnection No unit

With drain possibility connection:
Whether the boiler is suitable for drain connection (TRUE) or not (FALSE)

n/a
WithCleaningOpening No unit

With cleaning opening:
Whether the boiler has an opening for cleaning (TRUE) or not (FALSE)

n/a
WithPressureReducingValve No unit

With pressure reducing valve:
Whether the boiler has a valve for reducing pressure (TRUE) or not (FALSE)

n/a
WithThermometer No unit

With thermometer:
Whether the boiler has thermometer (TRUE) or not (FALSE)

n/a
WithProtectiveAnode No unit

With protective anode:
Whether the boiler has a protective anode to prevent tank wear (TRUE) or not (FALSE)

n/a
WithDraughtLimitingDevice No unit

With draught limiting device:
Whether the boiler has a draught-limiting device (TRUE) or not (FALSE)

n/a
AirSupplyConnection No unit

Air supply connection:
Type of air supply connection

n/a
FeulGasConnection No unit

Feul gas connection:
Type of flue gas connection

n/a
ColdTapWaterConnection No unit

Cold tap water connection:
Type of cold water connection

EN ISO 228-1

CondensateConnection No unit

Condensate connection:
Type of the condensate connection

EN ISO 228-1

CapacityProfile No unit

Capacity profile:
Capacity profile of the boiler. Ex.: XXXS, XXS, XS, S, M, L, XL, XXL

n/a
EnergyEfficiencyClass No unit

Energy efficiency class:
Energy efficiency class of the boiler. Ex.: A+++, A++, A+, A, B, C, D, E, F, G

n/a
HeatTransferSurfaceArea m2

Heat transfer surface area:
Total heat transfer area of the vessel

n/a
Diameter mm

Diameter:
Diameter of the cylindrical boiler in milimeters. It should only be provided if it is a cylindrical boiler

n/a
NominalDiameterFuel mm

Nominal diameter fuel:
Nominal diameter of the fuel pipe in milimeters

n/a
OuterPipeDiameterFuel mm

Outer pipe diameter fuel:
Outer diameter of the fuel pipe in milimeters

n/a
NominalDuctWidthAirSupply mm

Nominal duct width air supply:
Nominal width of air supply duct in milimeters

n/a
NominalDuctDiameterFlue mm

Nominal duct diameter flue:
Nominal diameter of the flue duct in milimeters

n/a
NominalDiameterColdTapWater mm

Nominal diameter cold tap water:
Nominal diameter of the cold water tap in milimeters

n/a
OuterPipeDiameterColdTapWater mm

Outer pipe diameter cold tap water:
Nominal outer diameter of the cold water tap in milimeters

n/a
OuterPipeDiameterCondensate mm

Outer pipe diameter condensate:
Outer diameter of condensate pipe in milimeters

n/a
ThicknessesMaterial mm

Thicknesses material:
Wall thicknesses of the boiler in milimeters

ISO EN 10029:2010

NominalHeight IFC Logo AlturaNominal mm

Nominal height:
Typically the vertical or secondary characteristic dimension, ex. 300

n/a
NominalLength IFC Logo ComprimentoNominal mm

Nominal length:
Typically the larger or primary horizontal dimension., ex. 5000

n/a
NominalWidth IFC Logo LarguraNominal mm

Nominal width:
Nominal width of product, typically the characteristic or secondary horizontal or characteristic dimension, ex. 200

n/a
Shape No unit

Shape:
Characteristic shape of product, ex. Rectangle

n/a
WaterHeatingEnergyEfficiency %

Water heating energy efficiency:
The water heating energy efficiency (?wh), in %, using GCV and including primary energy for electricity

EN ISO 13203-2:2015

AnnualElectricityConsumption kWh

Annual electricity consumption:
Annual electricity consumption in kWh

EN ISO 13203-2:2015

AnnualFuelConsumption GJ

Annual fuel consumption:
Annual fuel consumption in kWh

EN ISO 13203-2:2015

DailyGasEnergyConsumptionInSummerMode kWh

Daily gas energy consumption in summer mode:
The daily gas energy consumption in summer mode calculated using Net Calorific Value, in kWh

EN ISO 13203-2:2015

DailyGasEnergyConsumptionInWinterMode kWh

Daily gas energy consumption in winter mode:
The daily gas energy consumption calculated in winter mode using Net Calorific Value, in kWh

EN ISO 13203-2:2015

DailyGasEnergyConsumptionSeasonallyWeighted kWh

Daily gas energy consumption seasonally weighted:
The weighted daily gas energy consumption calculated using Net Calorific Value, in kWh

EN ISO 13203-2:2015

DailyGasEnergyConsumptionInStandbyMode kWh

Daily gas energy consumption in standby mode:
The daily gas energy consumption in standby mode calculated using Net Calorific Value, in kWh

EN ISO 13203-2:2015

DailyElectricalEnergy kWh

Daily electrical energy:
The daily electrical energy of all the electrical auxiliaries necessary to achieve the tapping programme(s) at nominal use as described in the appliance documentation

EN ISO 13203-2:2015

DailyAuxiliaryEnergyInStandbyMode kWh

Daily auxiliary energy in standby mode:
The daily consumption of auxiliary energy in standby mode, in kWh

EN ISO 13203-2:2015

DailyAuxiliaryEnergyConsumptionInOffMode kWh

Daily auxiliary energy consumption in off mode:
The daily consumption of auxiliary energy in off mode, in kWh

EN ISO 13203-2:2015

WarrantyContent IFC Logo ConteudoGarantia No unit

Warranty content:
A general description of the content of the warranty.

n/a
WarrantyDurationLabor No unit

Warranty duration labor:
Duration of labour warranty., ex. 5 years

n/a
WarrantyDurationParts No unit

Warranty duration parts:
Duration of parts warranty., ex. 5 years

n/a
WarrantyGuarantorLabor No unit

Warranty guarantor labor:
Email address for the organisation responsible for the labour warranty.

n/a
WarrantyGuarantorParts No unit

Warranty guarantor parts:
Email address for the organisation responsible for the parts warranty.

n/a
WarrantyStartDate IFC Logo DataInicioGarantia No unit

Warranty start date:
The date on which the warranty commences, ex. 31/12/1999 23:59:59

n/a
WarrantyIdentifier IFC Logo IdentificadorGarantia No unit

Warranty identifier:
The identifier assigned to a warranty

n/a
WarrantyEndDate No unit

Warranty end date:
The date on which the warranty expires, ex. 31/12/1999 23:59:59

n/a
IsExtendedWarranty IFC Logo GarantiaEAlargada No unit

Is extended warranty:
Indication of whether this is an extended warranty whose duration is greater than that normally assigned to an artefact (=TRUE) or not (= FALSE), ex. FALSE

n/a
Exclusions IFC Logo ExclusoesGarantia No unit

Exclusions:
Items, conditions or actions that may be excluded from the warranty or that may cause the warranty to become void

n/a
InstallationDate IFC Logo DataInstalacao No unit

Installation date:
The date that the manufactured item was installed (per instance), ex. 31/12/1999 23:59:59

n/a
InstallationLocation No unit

Installation location:
The location where the product is installed

n/a
IsReusable No unit

Is reusable:
Indication of whether this product is reusable (=TRUE) or not (= FALSE)

n/a
IsRemanufacturable No unit

Is remanufacturable:
Indication of whether this product is remanufacturable (=TRUE) or not (= FALSE)

n/a
IsUpgradable No unit

Is upgradable:
Indication of whether this product is upgradable (=TRUE) or not (= FALSE)

n/a
IsRepairable No unit

Is repairable:
Indication of whether this product is repairable (=TRUE) or not (= FALSE)

n/a
WasteGenerated No unit

Waste generated:
List of waste generated by the product, including packaging

n/a
ContaminatingWaste No unit

Contaminating waste:
Identify potentially contaminating waste/substances

n/a
DismantlingMethod No unit

Dismantling method:
Appropriate dismantling method for each waste (recycling, reuse, repair, resale, restoration, reincorporation, improvement)

n/a
REACHLabel No unit

Reach label:
Indication as to whether an article or ingredient of an article is subject to the REACH Regulation: articles and ingredients of articles that are listed as substances of very high concern under REACH have to be labelled in the data delivery. Allowed values: yes / no / no data. If REACH is not applicable e.g. services use (no). If REACH info is not available, use (no data).

n/a
REACHListDate No unit

Reach list date:
Date, on which the product was checked by the manufacturer for REACH.

n/a
SustainabilityPerformance No unit

Sustainability performance:
Description of the sustainability issue(s) which the object satisfies

n/a
IsItemNew No unit

Is item new:
Indication of whether this item is new (=TRUE) or not (= FALSE)

n/a
IsItemPartiallyRecycled No unit

Is item partially recycled:
Indication of whether this item is partially recycled (=TRUE) or not (= FALSE)

n/a
IsItemRecycled No unit

Is item recycled:
Indication of whether this item is totally recycled (=TRUE) or not (= FALSE)

n/a
ExpectedServiceLife No unit

Expected service life:
Expected service life in years, ex. 60 years

n/a
FunctionalUnitReference No unit

Functional unit reference:
Reference to a database or a classification, ex. EPD international

n/a
DangerousSubstances No unit

Dangerous substances:
Materials used in the product contain or release any dangerous substances as per European or any national standards ex. None

n/a
InertWaste IFC Logo ResiduosInertes kg

Inert waste:
Quantity of inert waste generated

n/a
AbioticDepletionPotentialForFossilResources MJ

Abiotic depletion potential for fossil resources:
defines the decreasing availability of non - renewable resources as a result of their extraction and underlaying scarcity, relating to fossil fuels

ISO 14025:2006

AbioticDepletionPotentialForNonFossilResourcesMineralsAndMetals kg Sb eq

Abiotic depletion potential for non fossil resources minerals and metals:
defines the decreasing availability of non - renewable resources as a result of their extraction and underlaying scarcity, relating to scarce elements and their ores

ISO 14025:2006

GlobalWarmingPotentialBiogenic kg CO2 eq

Global warming potential biogenic:
covers carbon emissions to air (CO2, CO and CH4) originating from the oxidation and/or reduction of aboveground biomass by means of its transformation or degradation (e.g. combustion, digestion, composting, landfilling) and CO2 uptake from the atmosphere through photosynthesis during biomass growth – i.e. corresponding to the carbon content of products, biofuels or above ground plant residues such as litter and dead wood

ISO 14025:2006

GlobalWarmingPotentialFossilFuels kg CO2 eq

Global warming potential fossil fuels:
it covers greenhouse gas (GHG) emissions to any media originating from the oxidation and/or reduction of fossil fuels by means of their transformation or degradation (e.g. combustion, digestion, landfilling, etc.)

ISO 14025:2006

GlobalWarmingPotentialLandUseAndLandUseChange kg CO2 eq

Global warming potential land use and land use change:
factor describing the potential radiative forcing impact of carbon uptakes and emissions (CO2, CO and CH4) originating from carbon stock changes caused by land use change and land use over a given period of time

ISO 14025:2006

GlobalWarmingPotentialTotal kg CO2 eq

Global warming potential total:
it accounts for the total global warming potential arising from fossil, biogenic and land use and land use change emissions

ISO 14025:2006

TroposphericOzoneConcentrationIncrease kg NMVOC eq

Tropospheric ozone concentration increase:
measure of the amoutn of ozone in the troposphere (at the earths surface) where it causes summer smog

ISO 14025:2006

DepletionPotentialOfTheStratosphericOzoneLayer kg CFC11 eq

Depletion potential of the stratospheric ozone layer:
the relative amount of degradation to the ozone layer a product can cause

ISO 14025:2006

AcidificationPotentialAccumulatedExceedance mol H+ eq

Acidification potential accumulated exceedance:
a measure of the acidification caused to land and water from emissions to air of acidifying substances

ISO 14025:2006

EutrophicationPotentialAccumulatedExceedance mol N eq

Eutrophication potential accumulated exceedance:
a measure of the eutrophication caused by emissions

ISO 14025:2006

EutrophicationPotentialFractionOfNutrientsReachingFreshwaterEndCompartment kg (PO4)^(3-) eq

Eutrophication potential fraction of nutrients reaching freshwater end compartment:
a measure of the eutrophication caused by emissions reaching freshwater

ISO 14025:2006

EutrophicationPotentialFractionOfNutrientsReachingMarineEndCompartment kg N eq

Eutrophication potential fraction of nutrients reaching marine end compartment:
a measure of the eutrophication caused by emissions reaching marine water

ISO 14025:2006

WaterDeprivationPotentialDeprivationWeightedWaterConsumption m3

Water deprivation potential deprivation weighted water consumption:
unit for the impact category water use

ISO 14025:2006

NonRenewablePrimaryResourcesUsedAsAnEnergyCarrierFuel MJ

Non renewable primary resources used as an energy carrier fuel:
Materials such as peat, oil, gas, coal, uranium used (first use) as an energy source.

ISO 14025:2006

NonRenewablePrimaryResourcesWithEnergyContentUsedAsMaterial MJ

Non renewable primary resources with energy content used as material:
Primary resources such as oil, gas and coal, used (first use) for products (e.g. plastic-based products).

ISO 14025:2006

NonRenewableSecondaryFuels MJ

Non renewable secondary fuels:
Non-renewable materials with energy content that have crossed the system boundary between product systems and are used as fuel input (energy source) in another product system (e.g. processed solvents, shredded tyres

ISO 14025:2006

RecoveredEnergy MJ

Recovered energy:
energy recovered from disposal of waste in previous systems, such as energy recovery from combustion of landfill gas or energy recovered from other systems using energy sources

ISO 14025:2006

RenewablePrimaryResourcesUsedAsAnEnergyCarrierFuel MJ

Renewable primary resources used as an energy carrier fuel:
Bio-based materials used (first use) as an energy source and hydropower, solar and wind power used in the technosphere are included.

ISO 14025:2006

RenewablePrimaryResourcesWithEnergyContentUsedAsMaterial MJ

Renewable primary resources with energy content used as material:
Bio-based materials used (first use) as materials (e.g. wood, hemp, etc.).

ISO 14025:2006

RenewableSecondaryFuels MJ

Renewable secondary fuels:
renewable materials with energy content that have crossed the system boundary between product systems and are used as fuel input (energy source) in another product system (e.g. biomass residue pellets, chipped waste wood)

ISO 14025:2006

SecondaryMaterials kg

Secondary materials:
material recovered from previous use or from waste which substitutes primary materials

ISO 14025:2006

ConsumptionOfFreshwater m3

Consumption of freshwater:
net freshwater entering the product system being studied that is not returned to the same drainage basin from which it originated

ISO 14025:2006

NetUseOfFreshwater m3

Net use of freshwater:
freshwater entering the product system being studied that is not returned to the same drainage basin from which it originated. Measured using the principles of water footprint inventory analysis according to ISO 14046.

ISO 14025:2006

HazardousWasteDisposed kg

Hazardous waste disposed:
hazardous waste to final repository

ISO 14025:2006

NonHazardousWasteDisposed kg

Non hazardous waste disposed:
Non-hazardous waste is non-toxic and similar to household waste. It consists of inert waste and ordinary household waste

ISO 14025:2006

TotalRadioactiveWasteDisposedMass kg

Total radioactive waste disposed mass:
The sum, in weight, high-, intermediate- and low-level radioactive waste, conditioned, to final repository

ISO 14025:2006

TotalRadioactiveWasteDisposedVolume m3

Total radioactive waste disposed volume:
The sum, in volume, of high-, intermediate- and low-level radioactive waste, conditioned, to final repository

ISO 14025:2006

ComponentsForReUse kg

Components for re use:
Amount of components which are reused at end-of-life

ISO 14025:2006

ExportedElectricalEnergy MJ

Exported electrical energy:
Amount of electrical energy available in the market after incineration

ISO 14025:2006

ExportedThermalEnergy MJ

Exported thermal energy:
Amount of thermal energy available in the market after incineration

ISO 14025:2006

MaterialsForEnergyRecovery kg

Materials for energy recovery:
Secondary fuels for use in the next product system

ISO 14025:2006

MaterialsForRecycling kg

Materials for recycling:
Secondary material for use in the next product system

ISO 14025:2006

LifeCyclePhase IFC Logo FaseDoCicloDeVida No unit

Life cycle phase:
The whole life cycle or only a given phase from which environmental data are valid, ex. A1- A3 (Production stage)

ISO 14025:2006

LifeCycleStagesOmitted No unit

Life cycle stages omitted:
Life cycle stages omitted from the Environmental Product Declaration calculations, ex. B1 - B7 (use stage), C1 - C4 (end of life stage).

ISO 14025:2006

EPDUnit No unit

EPD unit:
The unit of the quantity the environmental indicators values are related with, ex. 1 piece of steel door

ISO 14025:2006

Colour key — where each property comes from (IsSubtypeOf relation):
Own (this template) Inherited from: Master