ChannelForConcreteMortarInfill

- V1.1

Active

Property attributes in the data dictionary, per EN ISO 23386

GUID b402e999ea9f4c3186801bd27a6950d1
URI https://pdts.pt/uri/0.1/prop/AreaDoCanalDePreenchimentoDeArgamassa
Version: https://pdts.pt/uri/0.1/prop/AreaDoCanalDePreenchimentoDeArgamassa/v1
Name Channel for concrete mortar infill
Name (code form) ChannelForConcreteMortarInfill
Definition The perforation shall be arranged in such a way, that a vertically continuous channel is established if clay masonry units are set in bonds. The channel for concrete/mortar infill shall be arranged axial in direction of the unit's width. The channel for concrete/mortar infill shall have a minimum area of 1 500 mm2 and a minimum dimension of 30 mm
Units mm2
Visual representation
Status Active
Reference document

EN ISO 771-1:2011+A1:2015

Date of creation 2023-10-01
Date of activation 2023-10-01
Date of last change 2023-10-01
Date of revision 2023-10-01
Date of version 2023-10-01
Version 1
Revision 1
Replaced properties
Replacing properties
Relation to other data dictionaries
Creator’s language pt-PT
Country of use PT
Country of origin PT
Physical quantity square milli metre | en.EN
Dimension L2
Data type String
Dynamic property FALSE
Parameters of the dynamic property
Names of the defining values
Defining values
Tolerance
Digital format
Text format (UTF-8, 32)
List of possible values in language n
Boundary values
Deprecation explanation
Deprecation date

This property appears in:

Data template Property description
Clay brick V1.1 The perforation shall be arranged in such a way, that a vertically continuous channel is established if clay masonry units are set in bonds. The channel for concrete/mortar infill shall be arranged axial in direction of the unit's width. The channel for concrete/mortar infill shall have a minimum area of 1 500 mm2 and a minimum dimension of 30 mm
Clay brick V2.1 The perforation shall be arranged in such a way, that a vertically continuous channel is established if clay masonry units are set in bonds. The channel for concrete/mortar infill shall be arranged axial in direction of the unit's width. The channel for concrete/mortar infill shall have a minimum area of 1 500 mm2 and a minimum dimension of 30 mm