Product data template, per EN ISO 23387

Slab

- V1.1

Active
Property Unit Description Reference document
Classification<System><Table>Code No unit

Classification<System><Table>code:
Classification code of the product, ex. ClassificationSecclassProductsNumber = Pr_20_85_08

n/a
Classification<System><Table>Title No unit

Classification<System><Table>title:
Classification title of the product, ex. ClassificationSecclassProductsDescription = Timber beams

n/a
Classification<System><Table>Version No unit

Classification<System><Table>version:
Classification system version used, ex. ClassificationSecclassProductsVersion = v1.4

n/a
Name IFC Logo Nome No unit

Name:
The product name shall consist of the following fields: <Source>_<Type>_<Subtype>_<Differentiator_n>, ex. LEDSMART_Luminaire_Interior_1420x37x84mm. For more information, consult the standard draft Building Information Modelling (BIM) - Rules for the Modelling of BIM Objects and the link: https://secclass.pt/wp-content/uploads/2021/10/R_M_ObjectosBIM.pdf

n/a
CommercialName No unit

Commercial name:
The commercial name of the product, which usually is used to define the product for costumers

n/a
ProductType No unit

Product type:
The type of the product

n/a
Description IFC Logo Descricao No unit

Description:
A general description of the object

n/a
EPDRegistrationNumber No unit

EPD registration number:
Registration number of the Environmental Project Declaration document

n/a
ReferenceToOriginalEPD IFC Logo ReferenciaDAP No unit

Reference to original EPD:
a hyperlink to the original EPD according to standard PCR

n/a
DOPReference No unit

DOP reference:
Reference of the Declaration of Performance

n/a
UrlDOP No unit

URL DOP:
A URL to the DoP document (PDF, or digital version)

n/a
Manufacturer IFC Logo Fabricante No unit

Manufacturer:
The organization that manufactured and/or assembled the item

n/a
ManufacturerURL No unit

Manufacturer URL:
The website of the organization that manufactured and/or assembled the item

n/a
ManufacturerEmail No unit

Manufacturer email:
The email of the manufacturer

n/a
ManufacturerNumber No unit

Manufacturer number:
The contact number of the manufacturer

n/a
ModelReference IFC Logo ReferenciaModelo No unit

Model reference:
The model number or designator of the product model (or product line) as assigned by the manufacturer of the manufactured item, ex. ASMD Metal Door

n/a
BarCode IFC Logo CodigoDeBarras No unit

Bar code:
The identity of the bar code given to an occurrence of the product

n/a
SerialNumber IFC Logo NumeroDeSerie No unit

Serial number:
The serial number assigned to an occurrence of a product

n/a
GlobalTradeItemNumber IFC Logo NumeroGlobalDeItemComercial No unit

Global trade item number (GTIN):
The Global Trade Item Number (GTIN) is an identifier for trade items developed by GS1 (www.gs1.org), ex. 123456789012

n/a
ProductionDate No unit

Production date:
The date of production of the manufactured item, ex. 31/12/1999 23:59:59

n/a
AcquisitionDate IFC Logo DataAquisicao No unit

Acquisition date:
The date that the manufactured item was purchased, ex. 31/12/1999 23:59:59

n/a
NetWeight IFC Logo PesoLiquido kg

Net weight:
Element net weight excluding shipping packaging, ex. 60 kg

n/a
GrossWeight IFC Logo PesoBruto kg

Gross weight:
Element weight including shipping packaging, ex. 55 kg

n/a
MaterialWeight No unit

Material weight:
Weight of the referenced material in the product. ex. WoodWeight = 20

n/a
<Material>Origin No unit

<Material> origin:
Origin of the referenced material ex. WoodOrigin = Portugal

n/a
<Material>DPPurl No unit

<Material> DPP Url:
The URL that leads to the Digital Product Passport of the selected material

n/a
Packaging<Material>Weight No unit

Packaging <material> weight:
The weight of the packaging material referenced

n/a
ConceptualCost No unit

Conceptual cost:
Conceptual cost estimating is done during the pre-construction stage of a project, ex. 200 EUR

n/a
RecordedActualCost No unit

Recorded actual cost:
the actual cost of the asset , ex. 195EUR

n/a
ReplacementCost No unit

Replacement cost:
An indicative cost for unit replacement, ex. 200 EUR

n/a
FutureCostAssumptions No unit

Future cost assumptions:
Costs estimates for maintaining the element during its lifecycle, ex. 50EUR

n/a
ShippingCost No unit

Shipping cost:
Cost of shipping to installation location

n/a
Constituents No unit

Constituents:
Optional constituent features, parts or finishes, ex. Door with self closing lock

n/a
Color IFC Logo Cor No unit

Color:
Color selection for this object, ex. White, Brown, and Black

n/a
Category No unit

Category:
Category of the product when similar products exist belonging to the same product type. For example ceramic tiles have several categories that can be used in different context. Ex: Floor tile, Skirting, Wall tile, …

n/a
Finish IFC Logo Acabamento No unit

Finish:
Characteristic or primary finish of product

n/a
Features No unit

Features:
Other important characteristics or features relevant to product specification.

n/a
Material No unit

Material:
Characteristic or primary material of product., ex. Pine wood

n/a
FacilityIdentifier No unit

Facility identifier:
A unique identifier assigned to a physical location, such as a manufacturing plant, warehouse, or other facility, where specific activities related to a product occur. It is used to trace operations, ensure compliance, and maintain supply chain transparency.

n/a
EconomicOperatorIdentifier No unit

Economic operator identifier:
A unique identifier assigned to an entity responsible for the product at specific stages of its lifecycle, such as manufacturing, importing, or distribution. It ensures regulatory compliance, accountability, and traceability in the supply chain.

n/a
ManufacturerGLN No unit

Manufacturer GLN:
GLN- Global Location Number of the Manufacturer. This could be your local or headquarter GLN depending on point of origin, ex. 1234567890123

n/a
DataDeliveryCountry No unit

Data delivery country:
Country for which data delivery is planned. Territory (i.e. country, state, region) coded according to ISO 3166-1 Alpha2, ex. FR

n/a
DataDeliveryLanguage No unit

Data delivery language:
Basic language of the data delivery. This element specifies the used languages (acc. ISO 639-1), especially the default language of all language-dependent information, ex. fr

n/a
StartOfValidity No unit

Start of validity:
The start date of validity of the article, ex. 31/12/1999

n/a
EndOfValidity No unit

End of validity:
The end date of validity of the article, ex. 31/12/1999

n/a
<Attachment>Url No unit

<Attachment> Url:
URL to the referenced attachment/digital asset ex. ProductPhotourl = www.manufcaturer.com/product/photo

n/a
DeepLinkUrl No unit

Deep link URL:
A deep link (URL) redirects to a relevant webpage of the supplier or manufacturer company, where further information on the article may be found, ex. www.company.com/product

n/a
CountryOfOrigin No unit

Country of origin:
Country of origin is the country where the article was manufactured, or the last essential processing step was completed. Description of the country according to >>ISO-3166-1 Alpha2<< (Country Subdivision Codes). Country codes must be written in 2 capital letters, ex. PT

n/a
LocationOfOrigin No unit

Location of origin:
The location where the product was manufactured, can be the city or an address

n/a
ProductionProcessSummary No unit

Production process summary:
Stages of production

n/a
TransportType No unit

Transport type:
The type of transport used to distribute the product

n/a
PackagingType No unit

Packaging type:
The type of packaging used for the product

n/a
AcousticRating IFC Logo ClassificacaoAcustica W/m²K

Acoustic rating:
Acoustic rating for this object. It is giving according to the national building code. It indicates the sound transmission resistance of this object by an index ration (instead of providing full sound absorption values)

n/a
ThermalTransmittance IFC Logo TransmitanciaTermica W/m²K

Thermal transmittance:
Heat transfer coefficient (U-value) of the material layers. Here the total heat transfer coefficient of the beam (in the direction of the heat flow), given without the internal and external heat transfer resistance ex. 0.12

n/a
FireRating IFC Logo ClassificacaoFogo No unit

Fire rating:
Fire rating given according to the national fire safety classification. Declared reaction to fire Class A1 to F

n/a
Combustible No unit

Combustible:
Indication whether the object is made from combustible material (TRUE) or not (FALSE).

n/a
SurfaceSpreadOfFlame IFC Logo PropagacaoSuperficialChama No unit

Surface spread of flame:
Indicação sobre a forma como as chamas se propagam pela superfície, É dada de acordo com o código nacional de construção que rege o comportamento ao fogo dos materiais.

n/a
LoadBearing IFC Logo SuportaCargas No unit

Load bearing:
Indication of whether this component is load-bearing (TRUE) or non-load-bearing (FALSE) ex. FALSE

n/a
ExposureClass IFC Logo ClasseDeExposicao No unit

Exposure class:
Classification of exposure to environmental conditions, usually specified in accordance with the concrete design code which is applied in the project. ex. XC1 to XC3

n/a
DimensionalAccuracyClass IFC Logo ClasseDePrecisaoDimensional No unit

Dimensional accuracy class:
Classification designation of the dimensional accuracy requirement according to local standards.

n/a
ConstructionToleranceClass IFC Logo ClasseDeToleranciaDeConstrucao No unit

Construction tolerance class:
Classification designation of the on-site construction tolerances according to local standards.

n/a
StrengthClass IFC Logo ClasseDeResistencia No unit

Strength class:
Classification of the concrete strength in accordance with the concrete design code which is applied in the project. ex. C50/60

n/a
ReinforcementStrengthClass IFC Logo ClasseDeResistenciaDoReforco No unit

Reinforcement strength class:
Classification of the reinforcement strength in accordance with the concrete design code which is applied in the project. The reinforcing strength class often combines strength and ductility.

n/a
ReinforcementVolumeRatio IFC Logo RacioDoVolumeDeReforco kg/m³

Reinforcement volume ratio:
The required ratio of the effective mass of the reinforcement to the effective volume of the concrete of a reinforced concrete structural element.

n/a
ReinforcementAreaRatio IFC Logo RacioDeAreaDeReforco kg/m²

Reinforcement area ratio:
The required ratio of the effective area of the reinforcement to the effective area of the concrete At any section of a reinforced concrete structural element.

n/a
InitialTension IFC Logo TensaoInicial N/mm2

Initial tension:
The initial stress of the tendon. This property applies to prestressed concrete elements only.

n/a
FormStrippingStrength IFC Logo ResistenciaParaRemocaoDeForma MPa

Form stripping strength:
The minimum required strength of the concrete when the formwork is removed, ensuring that the structure remains intact without excessive deformation or failure. Ex. 20 Mpa

n/a
LiftingStrength IFC Logo ResistenciaParaElevacao kN

Lifting strength:
The minimum required compressive strength of the concrete when the concrete element is lifted.Ex. 20 kN

n/a
ReleaseStrength IFC Logo ResistenciaParaLiberacao MPa

Release strength:
The minimum required compressive strength of the concrete when the tendon stress is released. This ensures that the concrete has achieved sufficient strength to bear the load after the pre-stressing forces are removed. Ex. 30 Mpa

n/a
TransportationStrength IFC Logo ResistenciaParaTransporte rad

Transportation strength:
The minimum required compressive strength of the concrete required for transportation.

n/a
StructuralClass IFC Logo ClasseEstrutural No unit

Structural class:
The classification of the structural behavior or usage category of the product, typically defined according to engineering standards or design codes.

n/a
IsExternal IFC Logo EExterno No unit

Is external:
Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building

n/a
PieceMark IFC Logo MarcacaoDaPeca No unit

Piece mark:
Defines a unique piece for production purposes. All pieces with the same piece mark value are identical and interchangeable. The piece mark may be composed of sub-parts that have specific locally defined meaning (e.g. B-1A may denote a beam, of generic type ‘1’ and specific shape ‘A’).

n/a
ActualProductionDate IFC Logo DataRealDeProducao No unit

Actual production date:
Production date (stripped from form).

n/a
ManufacturingToleranceClass IFC Logo ClasseDeToleranciaDeFabricacao No unit

Manufacturing tolerance class:
Classification designation of the manufacturing tolerances according to local standards.

n/a
SupportDuringTransportDescription IFC Logo DescricaoDoSuporteDuranteOTransporte No unit

Support during transport description:
Textual description of how the concrete element is supported during transportation

n/a
SupportDuringTransportDocReference IFC Logo ReferenciaDeDocumentoDoSuporteDuranteOTransporte No unit

Support during transport doc reference:
Reference to an external document defining how the concrete element is supported during transportation

n/a
TendonRelaxation IFC Logo RelaxamentoDosTendoes %

Tendon relaxation:
The maximum allowable relaxation of the tendon (usually expressed as %/1000 h).This property applies to prestressed concrete elements only.

n/a
Compartmentation No unit

Compartmentation:
Indication whether the object is designed to serve as a fire compartmentation (TRUE) or not (FALSE)

n/a
ActualErectionDate IFC Logo DataDeMontagemReal No unit

Actual erection date:
The actual date on which the product or structure was erected or installed at its designated location.

n/a
AssemblyPlace IFC Logo LocalDeMontagem No unit

Assembly place:
The location where the product or its components are assembled, which can be either on-site or off-site.

n/a
CastingMethod IFC Logo MetodoDeMoldagem No unit

Casting method:
The method used to cast the element, indicating the process employed for shaping the concrete or material.

n/a
TypeDesignation IFC Logo DesignacaoDoTipo No unit

Type designation:
A classification or code that indicates the specific type, model, or version of the element, often related to design or usage.

n/a
HollowCorePlugging IFC Logo PlugagemDeNucleoVazio No unit

Hollow core plugging:
The process of sealing or filling the hollow core of a concrete element, often used for precast concrete components to ensure structural integrity and prevent water or debris from entering.

n/a
SurfaceGenusAfterFeatures IFC Logo GeneroDeSuperficieAposRecursos No unit

Surface genus after features:
The Surface Genus of the evaluated representation items after applying product-level geometric features such as openings and projections. Surface Genus is a topological measure that represents the number of 'holes' or 'handles' on a surface. For example, a sphere has genus 0, and a torus has genus 1.

n/a
SurfaceGenusBeforeFeatures IFC Logo GeneroDeSuperficieAntesDasCaracteristicas No unit

Surface genus before features:
The Surface Genus of the evaluated representation items before applying product-level geometric features, which refers to the general classification or characteristics of the surface prior to any geometric modifications or details being applied.

n/a
LongInSideCenterLowerBarPitch IFC Logo PassoBarraInferiorLongoCentroLado mm

Long in side center lower bar pitch:
The pitch for the lower reinforcement bar in the center of the long side.

n/a
LongInSideCenterTopBarPitch IFC Logo PassoBarraSuperiorLongoCentroLado mm

Long in side center top bar pitch:
The pitch for the top reinforcement bar in the center of the long side.

n/a
LongInSideEndLowerBarPitch IFC Logo PassoLongoBarraInferiorExtremidadeLateral mm

Long in side end lower bar pitch:
The pitch for the lower reinforcement bar at the end of the long side.

n/a
LongInSideEndTopBarPitch IFC Logo PassoLongoBarraSuperiorExtremidadeLateral mm

Long in side end top bar pitch:
The pitch for the top reinforcement bar at the end of the long side.

n/a
LongOutSideLowerBarPitch IFC Logo PassoLongoBarraInferiorLadoFora mm

Long out side lower bar pitch:
The pitch for the lower reinforcement bar at the outside of the long side.

n/a
LongOutSideTopBarPitch IFC Logo PassoBarraSuperiorLadoFora mm

Long out side top bar pitch:
The pitch for the top reinforcement bar at the outside of the long side.

n/a
ShortInSideCenterLowerBarPitch IFC Logo CurtoCentroLateralPassoBarraInferior mm

Short in side center lower bar pitch:
The pitch for the lower reinforcement bar in the center of the short side.

n/a
ShortInSideCenterTopBarPitch IFC Logo CurtoCentroLadoBarraSuperior mm

Short in side center top bar pitch:
The pitch for the top reinforcement bar in the center of the short side.

n/a
ShortInSideEndLowerBarPitch IFC Logo CurtoExtremidadeLateralBarraInferior mm

Short in side end lower bar pitch:
The pitch for the lower reinforcement bar at the end of the short side.

n/a
ShortInSideEndTopBarPitch IFC Logo CurtoExtremidadeLateralBarraSuperior mm

Short in side end top bar pitch:
The pitch for the top reinforcement bar at the end of the short side.

n/a
ShortOutSideLowerBarPitch IFC Logo PassoCurtoBarraInferiorLadoFora mm

Short out side lower bar pitch:
The pitch for the lower reinforcement bar at the outside of the short side.

n/a
ToppingType IFC Logo TipoTopo No unit

Topping type:
The type of topping applied to the element.

n/a
Perimeter mm

Perimeter:
Total perimeter of the element

n/a
GrossArea m2

Gross area:
Sum of all gross areas of the covering facing the space. No opening that is included in the covering is subtracted. ex. 2

n/a
NetArea m2

Net area:
Sum of all net areas of the covering facing the space. All openings that is included in the covering are subtracted. ex. 1.9

n/a
NetSurfaceArea m2

Net surface area:
Net surface of the element, all openings and recesses are deducted from the surface area ex. 8.06

n/a
GrossVolume IFC Logo VolumeBruto m3

Gross volume:
The volume of the element. All openings and recesses are included ex. 0.48

n/a
NetVolume m3

Net volume:
The total volume of the element, excluding any voids, cavities, or openings. This represents the effective solid material volume of the element. Ex. 2.3 m³

n/a
GrossSurfaceArea IFC Logo AreaSuperficialBruta m2

Gross surface area:
Total surface as the sum of surface area + (2 x cross-sectional area). It should only be specified if the lateral area and the cross-sectional area cannot be determined separately). ex. 8.06

n/a
ConcreteCover IFC Logo CobrimentoDeConcreto mm

Concrete cover:
The protective concrete cover at the reinforcing bars according to local building regulations. ex. 30

n/a
CornerChamfer IFC Logo ChanfroDeCanto mm

Corner chamfer:
The chamfer in the corners of the element. The chamfer is presumed to be equal in both directions.

n/a
Twisting IFC Logo Torcao deg

Twisting:
The angle, in radians, through which the end face of a precast piece is rotated with respect to its starting face, along its longitudinal axis, as a result of non-aligned supports. This measure is also termed the ‘warping’ angle.

n/a
MinimumAllowableSupportLength IFC Logo ComprimentoMinimoPermitidoDeSuporte mm

Minimum allowable support length:
The minimum allowable support length.

n/a
AsBuiltLocationNumber IFC Logo NumeroDeLocalizacaoConstruida No unit

As built location number:
Defines a unique location within a structure, the ‘slot’ into which the piece was installed. Where pieces share the same piece mark, they can be interchanged. The value is only known after erection.

n/a
DesignLocationNumber No unit

Design location number:
Defines a unique location within a structure, the ‘slot’ for which the piece was designed.

n/a
ConcreteCoverAtLinks IFC Logo CobrimentoDeConcretoNasLigaduras mm

Concrete cover at links:
The thickness of concrete between the links (stirrups) and the outer surface of the element. Ensures durability and structural integrity. Ex. 25 mm

n/a
ConcreteCoverAtMainBars IFC Logo CobrimentoDeConcretoNasBarrasPrincipais mm

Concrete cover at main bars:
The thickness of concrete between the main reinforcement bars and the outer surface of the element. Provides protection against environmental exposure and mechanical damage. Ex. 40 mm

n/a
BatterAtEnd IFC Logo InclinacaoNoFim deg

Batter at end:
The angle or degree of inclination at the end of the element, typically indicating how much the element deviates from a vertical or horizontal reference at its end. Ex. 5°

n/a
BatterAtStart IFC Logo InclinacaoNoInicio deg

Batter at start:
The angle or degree of inclination at the start of the element, typically indicating how much the element deviates from a vertical or horizontal reference at its starting point. Ex. 3°

n/a
CamberAtMidspan IFC Logo ArqueamentoNoMeioDoVao mm

Camber at midspan:
The vertical displacement or curvature of the element at its midpoint, typically designed to counteract deflections due to load. Ex. 10 mm

n/a
Shortening IFC Logo Encurtamento mm

Shortening:
The reduction in the length of a concrete element due to applied load or other factors such as temperature or shrinkage, typically observed in prestressed concrete elements.Ex. 10 mm

n/a
AngleBetweenComponentAxes IFC Logo AnguloEntreEixosComponentes deg

Angle between component axes:
The angle between the axes of the component.

n/a
AngleToFirstAxis IFC Logo AnguloRelacaoPrimeiroEixo deg

Angle to first axis:
The angle of the component relative to the first axis.

n/a
DistanceBetweenComponentAxes IFC Logo DistanciaEntreEixosComponentes mm

Distance between component axes:
The distance between the axes of the component.

n/a
EdgeDistanceToFirstAxis IFC Logo DistanciaBordaPrimeiroEixo mm

Edge distance to first axis:
The distance from the edge to the first axis.

n/a
NominalToppingThickness IFC Logo EspessuraNominalCobertura mm

Nominal topping thickness:
The nominal thickness of the topping.

n/a
PitchAngle IFC Logo AnguloRotacao deg

Pitch angle:
The angle of the element's pitch.

n/a
NominalHeight IFC Logo AlturaNominal mm

Nominal height:
Typically the vertical or secondary characteristic dimension, ex. 300

n/a
NominalLength IFC Logo ComprimentoNominal mm

Nominal length:
Typically the larger or primary horizontal dimension., ex. 5000

n/a
NominalWidth IFC Logo LarguraNominal mm

Nominal width:
Nominal width of product, typically the characteristic or secondary horizontal or characteristic dimension, ex. 200

n/a
Shape No unit

Shape:
Characteristic shape of product, ex. Rectangle

n/a
WarrantyContent IFC Logo ConteudoGarantia No unit

Warranty content:
A general description of the content of the warranty.

n/a
WarrantyDurationLabor No unit

Warranty duration labor:
Duration of labour warranty., ex. 5 years

n/a
WarrantyDurationParts No unit

Warranty duration parts:
Duration of parts warranty., ex. 5 years

n/a
WarrantyGuarantorLabor No unit

Warranty guarantor labor:
Email address for the organisation responsible for the labour warranty.

n/a
WarrantyGuarantorParts No unit

Warranty guarantor parts:
Email address for the organisation responsible for the parts warranty.

n/a
WarrantyStartDate IFC Logo DataInicioGarantia No unit

Warranty start date:
The date on which the warranty commences, ex. 31/12/1999 23:59:59

n/a
WarrantyIdentifier IFC Logo IdentificadorGarantia No unit

Warranty identifier:
The identifier assigned to a warranty

n/a
WarrantyEndDate No unit

Warranty end date:
The date on which the warranty expires, ex. 31/12/1999 23:59:59

n/a
IsExtendedWarranty IFC Logo GarantiaEAlargada No unit

Is extended warranty:
Indication of whether this is an extended warranty whose duration is greater than that normally assigned to an artefact (=TRUE) or not (= FALSE), ex. FALSE

n/a
Exclusions IFC Logo ExclusoesGarantia No unit

Exclusions:
Items, conditions or actions that may be excluded from the warranty or that may cause the warranty to become void

n/a
InstallationDate IFC Logo DataInstalacao No unit

Installation date:
The date that the manufactured item was installed (per instance), ex. 31/12/1999 23:59:59

n/a
InstallationLocation No unit

Installation location:
The location where the product is installed

n/a
IsReusable No unit

Is reusable:
Indication of whether this product is reusable (=TRUE) or not (= FALSE)

n/a
IsRemanufacturable No unit

Is remanufacturable:
Indication of whether this product is remanufacturable (=TRUE) or not (= FALSE)

n/a
IsUpgradable No unit

Is upgradable:
Indication of whether this product is upgradable (=TRUE) or not (= FALSE)

n/a
IsRepairable No unit

Is repairable:
Indication of whether this product is repairable (=TRUE) or not (= FALSE)

n/a
WasteGenerated No unit

Waste generated:
List of waste generated by the product, including packaging

n/a
ContaminatingWaste No unit

Contaminating waste:
Identify potentially contaminating waste/substances

n/a
DismantlingMethod No unit

Dismantling method:
Appropriate dismantling method for each waste (recycling, reuse, repair, resale, restoration, reincorporation, improvement)

n/a
REACHLabel No unit

Reach label:
Indication as to whether an article or ingredient of an article is subject to the REACH Regulation: articles and ingredients of articles that are listed as substances of very high concern under REACH have to be labelled in the data delivery. Allowed values: yes / no / no data. If REACH is not applicable e.g. services use (no). If REACH info is not available, use (no data).

n/a
REACHListDate No unit

Reach list date:
Date, on which the product was checked by the manufacturer for REACH.

n/a
SustainabilityPerformance No unit

Sustainability performance:
Description of the sustainability issue(s) which the object satisfies

n/a
IsItemNew No unit

Is item new:
Indication of whether this item is new (=TRUE) or not (= FALSE)

n/a
IsItemPartiallyRecycled No unit

Is item partially recycled:
Indication of whether this item is partially recycled (=TRUE) or not (= FALSE)

n/a
IsItemRecycled No unit

Is item recycled:
Indication of whether this item is totally recycled (=TRUE) or not (= FALSE)

n/a
ExpectedServiceLife No unit

Expected service life:
Expected service life in years, ex. 60 years

n/a
FunctionalUnitReference No unit

Functional unit reference:
Reference to a database or a classification, ex. EPD international

n/a
DangerousSubstances No unit

Dangerous substances:
Materials used in the product contain or release any dangerous substances as per European or any national standards ex. None

n/a
InertWaste IFC Logo ResiduosInertes kg

Inert waste:
Quantity of inert waste generated

n/a
AbioticDepletionPotentialForFossilResources MJ

Abiotic depletion potential for fossil resources:
defines the decreasing availability of non - renewable resources as a result of their extraction and underlaying scarcity, relating to fossil fuels

ISO 14025:2006

AbioticDepletionPotentialForNonFossilResourcesMineralsAndMetals kg Sb eq

Abiotic depletion potential for non fossil resources minerals and metals:
defines the decreasing availability of non - renewable resources as a result of their extraction and underlaying scarcity, relating to scarce elements and their ores

ISO 14025:2006

GlobalWarmingPotentialBiogenic kg CO2 eq

Global warming potential biogenic:
covers carbon emissions to air (CO2, CO and CH4) originating from the oxidation and/or reduction of aboveground biomass by means of its transformation or degradation (e.g. combustion, digestion, composting, landfilling) and CO2 uptake from the atmosphere through photosynthesis during biomass growth – i.e. corresponding to the carbon content of products, biofuels or above ground plant residues such as litter and dead wood

ISO 14025:2006

GlobalWarmingPotentialFossilFuels kg CO2 eq

Global warming potential fossil fuels:
it covers greenhouse gas (GHG) emissions to any media originating from the oxidation and/or reduction of fossil fuels by means of their transformation or degradation (e.g. combustion, digestion, landfilling, etc.)

ISO 14025:2006

GlobalWarmingPotentialLandUseAndLandUseChange kg CO2 eq

Global warming potential land use and land use change:
factor describing the potential radiative forcing impact of carbon uptakes and emissions (CO2, CO and CH4) originating from carbon stock changes caused by land use change and land use over a given period of time

ISO 14025:2006

GlobalWarmingPotentialTotal kg CO2 eq

Global warming potential total:
it accounts for the total global warming potential arising from fossil, biogenic and land use and land use change emissions

ISO 14025:2006

TroposphericOzoneConcentrationIncrease kg NMVOC eq

Tropospheric ozone concentration increase:
measure of the amoutn of ozone in the troposphere (at the earths surface) where it causes summer smog

ISO 14025:2006

DepletionPotentialOfTheStratosphericOzoneLayer kg CFC11 eq

Depletion potential of the stratospheric ozone layer:
the relative amount of degradation to the ozone layer a product can cause

ISO 14025:2006

AcidificationPotentialAccumulatedExceedance mol H+ eq

Acidification potential accumulated exceedance:
a measure of the acidification caused to land and water from emissions to air of acidifying substances

ISO 14025:2006

EutrophicationPotentialAccumulatedExceedance mol N eq

Eutrophication potential accumulated exceedance:
a measure of the eutrophication caused by emissions

ISO 14025:2006

EutrophicationPotentialFractionOfNutrientsReachingFreshwaterEndCompartment kg (PO4)^(3-) eq

Eutrophication potential fraction of nutrients reaching freshwater end compartment:
a measure of the eutrophication caused by emissions reaching freshwater

ISO 14025:2006

EutrophicationPotentialFractionOfNutrientsReachingMarineEndCompartment kg N eq

Eutrophication potential fraction of nutrients reaching marine end compartment:
a measure of the eutrophication caused by emissions reaching marine water

ISO 14025:2006

WaterDeprivationPotentialDeprivationWeightedWaterConsumption m3

Water deprivation potential deprivation weighted water consumption:
unit for the impact category water use

ISO 14025:2006

NonRenewablePrimaryResourcesUsedAsAnEnergyCarrierFuel MJ

Non renewable primary resources used as an energy carrier fuel:
Materials such as peat, oil, gas, coal, uranium used (first use) as an energy source.

ISO 14025:2006

NonRenewablePrimaryResourcesWithEnergyContentUsedAsMaterial MJ

Non renewable primary resources with energy content used as material:
Primary resources such as oil, gas and coal, used (first use) for products (e.g. plastic-based products).

ISO 14025:2006

NonRenewableSecondaryFuels MJ

Non renewable secondary fuels:
Non-renewable materials with energy content that have crossed the system boundary between product systems and are used as fuel input (energy source) in another product system (e.g. processed solvents, shredded tyres

ISO 14025:2006

RecoveredEnergy MJ

Recovered energy:
energy recovered from disposal of waste in previous systems, such as energy recovery from combustion of landfill gas or energy recovered from other systems using energy sources

ISO 14025:2006

RenewablePrimaryResourcesUsedAsAnEnergyCarrierFuel MJ

Renewable primary resources used as an energy carrier fuel:
Bio-based materials used (first use) as an energy source and hydropower, solar and wind power used in the technosphere are included.

ISO 14025:2006

RenewablePrimaryResourcesWithEnergyContentUsedAsMaterial MJ

Renewable primary resources with energy content used as material:
Bio-based materials used (first use) as materials (e.g. wood, hemp, etc.).

ISO 14025:2006

RenewableSecondaryFuels MJ

Renewable secondary fuels:
renewable materials with energy content that have crossed the system boundary between product systems and are used as fuel input (energy source) in another product system (e.g. biomass residue pellets, chipped waste wood)

ISO 14025:2006

SecondaryMaterials kg

Secondary materials:
material recovered from previous use or from waste which substitutes primary materials

ISO 14025:2006

ConsumptionOfFreshwater m3

Consumption of freshwater:
net freshwater entering the product system being studied that is not returned to the same drainage basin from which it originated

ISO 14025:2006

NetUseOfFreshwater m3

Net use of freshwater:
freshwater entering the product system being studied that is not returned to the same drainage basin from which it originated. Measured using the principles of water footprint inventory analysis according to ISO 14046.

ISO 14025:2006

HazardousWasteDisposed kg

Hazardous waste disposed:
hazardous waste to final repository

ISO 14025:2006

NonHazardousWasteDisposed kg

Non hazardous waste disposed:
Non-hazardous waste is non-toxic and similar to household waste. It consists of inert waste and ordinary household waste

ISO 14025:2006

TotalRadioactiveWasteDisposedMass kg

Total radioactive waste disposed mass:
The sum, in weight, high-, intermediate- and low-level radioactive waste, conditioned, to final repository

ISO 14025:2006

TotalRadioactiveWasteDisposedVolume m3

Total radioactive waste disposed volume:
The sum, in volume, of high-, intermediate- and low-level radioactive waste, conditioned, to final repository

ISO 14025:2006

ComponentsForReUse kg

Components for re use:
Amount of components which are reused at end-of-life

ISO 14025:2006

ExportedElectricalEnergy MJ

Exported electrical energy:
Amount of electrical energy available in the market after incineration

ISO 14025:2006

ExportedThermalEnergy MJ

Exported thermal energy:
Amount of thermal energy available in the market after incineration

ISO 14025:2006

MaterialsForEnergyRecovery kg

Materials for energy recovery:
Secondary fuels for use in the next product system

ISO 14025:2006

MaterialsForRecycling kg

Materials for recycling:
Secondary material for use in the next product system

ISO 14025:2006

LifeCyclePhase IFC Logo FaseDoCicloDeVida No unit

Life cycle phase:
The whole life cycle or only a given phase from which environmental data are valid, ex. A1- A3 (Production stage)

ISO 14025:2006

LifeCycleStagesOmitted No unit

Life cycle stages omitted:
Life cycle stages omitted from the Environmental Product Declaration calculations, ex. B1 - B7 (use stage), C1 - C4 (end of life stage).

ISO 14025:2006

EPDUnit No unit

EPD unit:
The unit of the quantity the environmental indicators values are related with, ex. 1 piece of steel door

ISO 14025:2006

Colour key — where each property comes from (IsSubtypeOf relation):
Own (this template) Inherited from: Master