Product data template, per EN ISO 23387

sink

- V1.1

Active
Property Unit Description Reference document
Classification<System><Table>Code No unit

Classification<System><Table>code:
Classification code of the product, ex. ClassificationSecclassProductsNumber = Pr_20_85_08

n/a
Classification<System><Table>Title No unit

Classification<System><Table>title:
Classification title of the product, ex. ClassificationSecclassProductsDescription = Timber beams

n/a
Classification<System><Table>Version No unit

Classification<System><Table>version:
Classification system version used, ex. ClassificationSecclassProductsVersion = v1.4

n/a
Name IFC Logo Nome No unit

Name:
The product name shall consist of the following fields: <Source>_<Type>_<Subtype>_<Differentiator_n>, ex. LEDSMART_Luminaire_Interior_1420x37x84mm. For more information, consult the standard draft Building Information Modelling (BIM) - Rules for the Modelling of BIM Objects and the link: https://secclass.pt/wp-content/uploads/2021/10/R_M_ObjectosBIM.pdf

n/a
CommercialName No unit

Commercial name:
The commercial name of the product, which usually is used to define the product for costumers

n/a
ProductType No unit

Product type:
The type of the product

n/a
Description IFC Logo Descricao No unit

Description:
A general description of the object

n/a
EPDRegistrationNumber No unit

EPD registration number:
Registration number of the Environmental Project Declaration document

n/a
ReferenceToOriginalEPD IFC Logo ReferenciaDAP No unit

Reference to original EPD:
a hyperlink to the original EPD according to standard PCR

n/a
DOPReference No unit

DOP reference:
Reference of the Declaration of Performance

n/a
UrlDOP No unit

URL DOP:
A URL to the DoP document (PDF, or digital version)

n/a
Manufacturer IFC Logo Fabricante No unit

Manufacturer:
The organization that manufactured and/or assembled the item

n/a
ManufacturerURL No unit

Manufacturer URL:
The website of the organization that manufactured and/or assembled the item

n/a
ManufacturerEmail No unit

Manufacturer email:
The email of the manufacturer

n/a
ManufacturerNumber No unit

Manufacturer number:
The contact number of the manufacturer

n/a
ModelReference IFC Logo ReferenciaModelo No unit

Model reference:
The model number or designator of the product model (or product line) as assigned by the manufacturer of the manufactured item, ex. ASMD Metal Door

n/a
BarCode IFC Logo CodigoDeBarras No unit

Bar code:
The identity of the bar code given to an occurrence of the product

n/a
SerialNumber IFC Logo NumeroDeSerie No unit

Serial number:
The serial number assigned to an occurrence of a product

n/a
GlobalTradeItemNumber IFC Logo NumeroGlobalDeItemComercial No unit

Global trade item number (GTIN):
The Global Trade Item Number (GTIN) is an identifier for trade items developed by GS1 (www.gs1.org), ex. 123456789012

n/a
ProductionDate No unit

Production date:
The date of production of the manufactured item, ex. 31/12/1999 23:59:59

n/a
AcquisitionDate IFC Logo DataAquisicao No unit

Acquisition date:
The date that the manufactured item was purchased, ex. 31/12/1999 23:59:59

n/a
NetWeight IFC Logo PesoLiquido kg

Net weight:
Element net weight excluding shipping packaging, ex. 60 kg

n/a
GrossWeight IFC Logo PesoBruto kg

Gross weight:
Element weight including shipping packaging, ex. 55 kg

n/a
MaterialWeight No unit

Material weight:
Weight of the referenced material in the product. ex. WoodWeight = 20

n/a
<Material>Origin No unit

<Material> origin:
Origin of the referenced material ex. WoodOrigin = Portugal

n/a
<Material>DPPurl No unit

<Material> DPP Url:
The URL that leads to the Digital Product Passport of the selected material

n/a
Packaging<Material>Weight No unit

Packaging <material> weight:
The weight of the packaging material referenced

n/a
ConceptualCost No unit

Conceptual cost:
Conceptual cost estimating is done during the pre-construction stage of a project, ex. 200 EUR

n/a
RecordedActualCost No unit

Recorded actual cost:
the actual cost of the asset , ex. 195EUR

n/a
ReplacementCost No unit

Replacement cost:
An indicative cost for unit replacement, ex. 200 EUR

n/a
FutureCostAssumptions No unit

Future cost assumptions:
Costs estimates for maintaining the element during its lifecycle, ex. 50EUR

n/a
ShippingCost No unit

Shipping cost:
Cost of shipping to installation location

n/a
Constituents No unit

Constituents:
Optional constituent features, parts or finishes, ex. Door with self closing lock

n/a
Color IFC Logo Cor No unit

Color:
Color selection for this object, ex. White, Brown, and Black

n/a
Category No unit

Category:
Category of the product when similar products exist belonging to the same product type. For example ceramic tiles have several categories that can be used in different context. Ex: Floor tile, Skirting, Wall tile, …

n/a
Finish IFC Logo Acabamento No unit

Finish:
Characteristic or primary finish of product

n/a
Features No unit

Features:
Other important characteristics or features relevant to product specification.

n/a
Material No unit

Material:
Characteristic or primary material of product., ex. Pine wood

n/a
FacilityIdentifier No unit

Facility identifier:
A unique identifier assigned to a physical location, such as a manufacturing plant, warehouse, or other facility, where specific activities related to a product occur. It is used to trace operations, ensure compliance, and maintain supply chain transparency.

n/a
EconomicOperatorIdentifier No unit

Economic operator identifier:
A unique identifier assigned to an entity responsible for the product at specific stages of its lifecycle, such as manufacturing, importing, or distribution. It ensures regulatory compliance, accountability, and traceability in the supply chain.

n/a
ManufacturerGLN No unit

Manufacturer GLN:
GLN- Global Location Number of the Manufacturer. This could be your local or headquarter GLN depending on point of origin, ex. 1234567890123

n/a
DataDeliveryCountry No unit

Data delivery country:
Country for which data delivery is planned. Territory (i.e. country, state, region) coded according to ISO 3166-1 Alpha2, ex. FR

n/a
DataDeliveryLanguage No unit

Data delivery language:
Basic language of the data delivery. This element specifies the used languages (acc. ISO 639-1), especially the default language of all language-dependent information, ex. fr

n/a
StartOfValidity No unit

Start of validity:
The start date of validity of the article, ex. 31/12/1999

n/a
EndOfValidity No unit

End of validity:
The end date of validity of the article, ex. 31/12/1999

n/a
<Attachment>Url No unit

<Attachment> Url:
URL to the referenced attachment/digital asset ex. ProductPhotourl = www.manufcaturer.com/product/photo

n/a
DeepLinkUrl No unit

Deep link URL:
A deep link (URL) redirects to a relevant webpage of the supplier or manufacturer company, where further information on the article may be found, ex. www.company.com/product

n/a
CountryOfOrigin No unit

Country of origin:
Country of origin is the country where the article was manufactured, or the last essential processing step was completed. Description of the country according to >>ISO-3166-1 Alpha2<< (Country Subdivision Codes). Country codes must be written in 2 capital letters, ex. PT

n/a
LocationOfOrigin No unit

Location of origin:
The location where the product was manufactured, can be the city or an address

n/a
ProductionProcessSummary No unit

Production process summary:
Stages of production

n/a
TransportType No unit

Transport type:
The type of transport used to distribute the product

n/a
PackagingType No unit

Packaging type:
The type of packaging used for the product

n/a
Cleanability No unit

Cleanability:
Cleanability refers to the ease and effectiveness with which something can be cleaned to remove dirt, bacteria, and other contaminants, ex. Pass

EN 13310:2003

ResistanceToDryHeat No unit

Resistance to dry heat:
Performance describing the resistance to dry heat. When tested as per standard, it is intended to determine the suitability of kitchen sink surfaces where contact with moderately hot cooking pots is to be expected, ex. Pass

EN 13310:2003

LoadResistance No unit

Load resistance:
Performance describing the load stability of the sink if it is wall hung. The wall-hung sink shall not crack, fall down or show permanent distortion, ex. Pass

EN 13310:2003

ResistanceToTemperatureChanges No unit

Resistance to temperature changes:
Performance describing the resistance to temperate changes. The kitchen sink shall not show surface changes which influence its intended usage, like cracks and de-lamination, ex. Pass

EN 13310:2003

ResistanceAgainstChemicalsAndStainingAgents No unit

Resistance against chemicals and staining agents:
Performance describing the resistance of Kitchen sinks. When used as intended, it shall be resistant to household chemicals, foodstuffs and cleansing agents, ex. Pass

EN 13310:2003

ResistanceToAbrasion No unit

Resistance to abrasion:
Description:This requirement is applicable only to multi-layer kitchen sinks to ensure the stability of the top layer. When tested in accordance to standard, the top layer of the test specimen shall not be abraded through, ex. Pass

EN 13310:2003

ResistanceToScratching No unit

Resistance to scratching:
This requirement is applicable only to multi-layer kitchen sinks to ensure the stability of the top layer. When tested in accordance to standard, any scratch shall not exceed 0,1 mm and/or the total depth of the top layer whichever is the least, ex. Pass

EN 13310:2003

FlowRateOfOverflow l/s

Flow rate of overflow:
Every kitchen sink shall be protected against overflowing. When tested in accordance to standards, the flow rate of the overflow shall not be less than 0,20 l/s. If no over flow hole exist, the value should be zero, ex. 0.3

EN 13310:2003

Durability No unit

Durability:
Indication whether kitchen sink passes conformity requirements of durability, ex. Pass

EN 13310:2003

BowlsNumber No unit

Bowls number:
Number of basins, ex. 1

n/a
TapHoleLocation No unit

Tap hole location:
The location of the tap holes in the kitchen sink, ex. First, center; Second, left.

n/a
WasteHoleLocation No unit

Waste hole location:
The location of the waste hole in the kitchen sink, ex. First, center; Second, left.

n/a
IntegralAccessories No unit

Integral accessories:
Any type of accessory for the kitchen sink, ex. Garbage disposal unit, or standpipe.

n/a
SinkType No unit

Sink type:
Selection of the type of sink from an enumeration of types. Enumerations: BELFAST, BUCKET, CLEANERS, COMBINATION_LEFT, COMBINATION_RIGHT, COMBINATION_DOUBLE, DRIP, LABORATORY, LONDON, PLASTER, POT, RINSING, SHELF, VEGETABLEPREPARATION, OTHER, NOTKNOWN, ex. BUCKET

n/a
Mounting IFC Logo Montagem No unit

Mounting:
Selection of the form of mounting of the sink from an enumeration of types. Enumerations: PEDESTAL, COUNTERTOP, WALLHUNG, SIT_ON, IN_SET, FLUSH_FIT, UNDER_MOUNTED, OTHER, NOTKNOWN, ex. WALLHUNG

n/a
ShutOffSectionType No unit

Shut off section type:
Indication of the type of shut off section, ex. smooth shutoff.

n/a
TypeOfFastening No unit

Type of fastening:
Type of fixation of the sink into the structure that holds it, ex. suspension hooks

n/a
WithDrainPlug No unit

With drain plug:
Indication whether the product has a drain plug (TRUE) or not (FALSE)

n/a
WithRecessForSoapDispenser No unit

With recess for soap dispenser:
Indication whether the product has a recess for soap dispenser (TRUE) or not (FALSE)

n/a
AntiBacterialTreatment No unit

Anti bacterial treatment:
An indication whether the kitchen sink has antibacterial treatment (TRUE) or not (FALSE)

n/a
WithMountingMaterial No unit

With mounting material:
An indication whether the product comes with mounting materials such as screws and hooks (TRUE) or not (FALSE)

n/a
WithEarthingFeature No unit

With earthing feature:
Indication whether the product has an earthing feature (TRUE) or not (FALSE)

n/a
WithTap No unit

With tap:
Indication whether the product comes with a tap (TRUE) or not (FALSE)

n/a
MountingOffset IFC Logo OffsetDeMontagem mm

Mounting offset:
For counter top mounted sinks, the vertical offset between the top of the sink and the counter top, ex. 15

MountingOffset

EN 695:2005

WasteOutletHoleDiameter mm

Waste outlet hole diameter:
Diameter of waste outlet hole or punched grill. D2 = 50 to 55, ex. 52

WasteOutletHoleDiameter

EN 695:2005

DistanceFromDiameterWasteOutletToUndersideDiameter mm

Distance from diameter waste outlet to underside diameter:
Distance between the reference diameter of the waste outlet and the underside of the waste outlet hole. h2= 2 to 25, ex. 30

DistanceFromDiameterWasteOutletToUndersideDiameter

EN 695:2005

BowlBottomToWasteOutletHoleDiameterReference mm

Bowl bottom to waste outlet hole diameter reference:
Distance between the surface bottom of the bowl and the reference diameter of the waste outlet. e >= 2, ex. 3

BowlBottomToWasteOutletHoleDiameterReference

EN 695:2005

WasteOutletHoleSealingSurfaceUpperSide mm

Waste outlet hole sealing surface upper side:
Waste outlet hole-sealing surface for the upper side. Symbol S1, ex. 3

WasteOutletHoleSealingSurfaceUpperSide

EN 695:2005

WasteOutletHoleSealingSurfaceUnderSide mm

Waste outlet hole sealing surface under side:
Waste outlet hole-sealing surface for the underside. S2 >= 3, ex. 5

WasteOutletHoleSealingSurfaceUnderSide

EN 695:2005

TapHoleDiameter mm

Tap hole diameter:
Diameter of tap hole. d2 = 34 a 37, ex. 35

TapHoleDiameter

EN 695:2005

TapPedestalClearanceDiameter mm

Tap pedestal clearance diameter:
Diameter of the clearance for the tap pedestal. d3 >= 64, ex. 65

TapPedestalClearanceDiameter

EN 695:2005

TapHoleMaterialThickness mm

Tap hole material thickness:
Thickness of the material in the area of the tap hole. s <= 18, ex. 20

TapHoleMaterialThickness

EN 695:2005

ClearanceTapHoleCenterMin mm

Clearance tap hole center min:
Clearance radius of a cylinder having the same centre line as the tap hole of a depth 0 mm to 5 mm from the lower plane of the tap hole. r >= 25, ex. 25

ClearanceTapHoleCenterMin

EN 695:2005

ClearanceTapHoleCenterMax mm

Clearance tap hole center max:
Clearance radius of a cylinder having the same centre line as the tap hole of a depth of min. 5 mm from the lower plane of the tap hole. r1 >=30, ex. 30

ClearanceTapHoleCenterMax

EN 695:2005

ToolAccessibilityClearance mm

Tool accessibility clearance:
Difference in level between r and r1 for tool accessibility. x <= 5, ex. 5

ToolAccessibilityClearance

EN 695:2005

TapHoleCentreToBowlEdge mm

Tap hole centre to bowl edge:
Distance between the centre line of the tap hole and the nearest edge of the bowl for choice of tap. Symbol g1, ex. 70

TapHoleCentreToBowlEdge

EN 695:2005

DistanceBetweenTapHolesCentres mm

Distance between tap holes centres:
Distance between the centre lines of the tap holes. g2 = 175 to 185, ex. 185

DistanceBetweenTapHolesCentres

EN 695:2005

WasteOutletCenterToOverflowHoleCenter mm

Waste outlet center to overflow hole center:
Distance from the centre of the waste outlet to a vertical line drawn from the centre of the overflow hole. a <= 120, ex. 110

WasteOutletCenterToOverflowHoleCenter

EN 695:2005

OverflowHoleCenterToWasteOutletHoleUnderside mm

Overflow hole center to waste outlet hole underside:
Distance from the horizontal drawn through the centre of the overflow hole and the underside of the waste outlet hole. H1 = 110 to 180, ex. 150

OverflowHoleCenterToWasteOutletHoleUnderside

EN 695:2005

OverflowHoleDepth mm

Overflow hole depth:
Depth of the overflow hole, for rectangular overflow holes. H2 = 24.5 to 25, ex. 25

OverflowHoleDepth

EN 695:2005

OverflowHoleWidth mm

Overflow hole width:
Width of the overflow hole, for rectangular overflow holes. B1 = 52.5 to 53, ex. 53

OverflowHoleWidth

EN 695:2005

OverflowHoleClearanceWidth mm

Overflow hole clearance width:
Width of the clearance of the overflow hole, for rectangular overflow holes. B2 >= 58, ex. 60

OverflowHoleClearanceWidth

EN 695:2005

OverflowHoleClearanceDepth mm

Overflow hole clearance depth:
Depth of the clearance of the overflow hole, for rectangular overflow holes. H3 >= 30, ex. 32

OverflowHoleClearanceDepth

EN 695:2005

SpillOverLevelToOverflowHoleTop mm

Spill over level to overflow hole top:
Distance between spill-over level of the kitchen sink and top of overflow hole. H4 >= 15, ex. 17

SpillOverLevelToOverflowHoleTop

EN 695:2005

OverflowHoleDiameter mm

Overflow hole diameter:
Diameter of the overflow hole, for circular overflow holes. D1 = 31 to 34, ex. 32

OverflowHoleDiameter

EN 695:2005

ClearanceOfOverflowHole mm

Clearance of overflow hole:
Clearance in the area of overflow hole, for circular overflow holes. D4 >= 36, ex. 38

ClearanceOfOverflowHole

EN 695:2005

DistanceBetweenWasteOutletHolesCentreLines mm

Distance between waste outlet holes centre lines:
Distance between centre lines of waste outlet holes. X <= 400, ex. 350

DistanceBetweenWasteOutletHolesCentreLines

EN 695:2005

OverflowHoleMaterialThickness mm

Overflow hole material thickness:
Thickness of the material in the area of the overflow hole. s2 <= 25, ex. 24

OverflowHoleMaterialThickness

EN 695:2005

NominalHeight IFC Logo AlturaNominal mm

Nominal height:
Typically the vertical or secondary characteristic dimension, ex. 300

n/a
NominalLength IFC Logo ComprimentoNominal mm

Nominal length:
Typically the larger or primary horizontal dimension., ex. 5000

n/a
NominalWidth IFC Logo LarguraNominal mm

Nominal width:
Nominal width of product, typically the characteristic or secondary horizontal or characteristic dimension, ex. 200

n/a
Shape No unit

Shape:
Characteristic shape of product, ex. Rectangle

n/a
WarrantyContent IFC Logo ConteudoGarantia No unit

Warranty content:
A general description of the content of the warranty.

n/a
WarrantyDurationLabor No unit

Warranty duration labor:
Duration of labour warranty., ex. 5 years

n/a
WarrantyDurationParts No unit

Warranty duration parts:
Duration of parts warranty., ex. 5 years

n/a
WarrantyGuarantorLabor No unit

Warranty guarantor labor:
Email address for the organisation responsible for the labour warranty.

n/a
WarrantyGuarantorParts No unit

Warranty guarantor parts:
Email address for the organisation responsible for the parts warranty.

n/a
WarrantyStartDate IFC Logo DataInicioGarantia No unit

Warranty start date:
The date on which the warranty commences, ex. 31/12/1999 23:59:59

n/a
WarrantyIdentifier IFC Logo IdentificadorGarantia No unit

Warranty identifier:
The identifier assigned to a warranty

n/a
WarrantyEndDate No unit

Warranty end date:
The date on which the warranty expires, ex. 31/12/1999 23:59:59

n/a
IsExtendedWarranty IFC Logo GarantiaEAlargada No unit

Is extended warranty:
Indication of whether this is an extended warranty whose duration is greater than that normally assigned to an artefact (=TRUE) or not (= FALSE), ex. FALSE

n/a
Exclusions IFC Logo ExclusoesGarantia No unit

Exclusions:
Items, conditions or actions that may be excluded from the warranty or that may cause the warranty to become void

n/a
InstallationDate IFC Logo DataInstalacao No unit

Installation date:
The date that the manufactured item was installed (per instance), ex. 31/12/1999 23:59:59

n/a
InstallationLocation No unit

Installation location:
The location where the product is installed

n/a
IsReusable No unit

Is reusable:
Indication of whether this product is reusable (=TRUE) or not (= FALSE)

n/a
IsRemanufacturable No unit

Is remanufacturable:
Indication of whether this product is remanufacturable (=TRUE) or not (= FALSE)

n/a
IsUpgradable No unit

Is upgradable:
Indication of whether this product is upgradable (=TRUE) or not (= FALSE)

n/a
IsRepairable No unit

Is repairable:
Indication of whether this product is repairable (=TRUE) or not (= FALSE)

n/a
WasteGenerated No unit

Waste generated:
List of waste generated by the product, including packaging

n/a
ContaminatingWaste No unit

Contaminating waste:
Identify potentially contaminating waste/substances

n/a
DismantlingMethod No unit

Dismantling method:
Appropriate dismantling method for each waste (recycling, reuse, repair, resale, restoration, reincorporation, improvement)

n/a
REACHLabel No unit

Reach label:
Indication as to whether an article or ingredient of an article is subject to the REACH Regulation: articles and ingredients of articles that are listed as substances of very high concern under REACH have to be labelled in the data delivery. Allowed values: yes / no / no data. If REACH is not applicable e.g. services use (no). If REACH info is not available, use (no data).

n/a
REACHListDate No unit

Reach list date:
Date, on which the product was checked by the manufacturer for REACH.

n/a
SustainabilityPerformance No unit

Sustainability performance:
Description of the sustainability issue(s) which the object satisfies

n/a
IsItemNew No unit

Is item new:
Indication of whether this item is new (=TRUE) or not (= FALSE)

n/a
IsItemPartiallyRecycled No unit

Is item partially recycled:
Indication of whether this item is partially recycled (=TRUE) or not (= FALSE)

n/a
IsItemRecycled No unit

Is item recycled:
Indication of whether this item is totally recycled (=TRUE) or not (= FALSE)

n/a
ExpectedServiceLife No unit

Expected service life:
Expected service life in years, ex. 60 years

n/a
FunctionalUnitReference No unit

Functional unit reference:
Reference to a database or a classification, ex. EPD international

n/a
DangerousSubstances No unit

Dangerous substances:
Materials used in the product contain or release any dangerous substances as per European or any national standards ex. None

n/a
InertWaste IFC Logo ResiduosInertes kg

Inert waste:
Quantity of inert waste generated

n/a
AbioticDepletionPotentialForFossilResources MJ

Abiotic depletion potential for fossil resources:
defines the decreasing availability of non - renewable resources as a result of their extraction and underlaying scarcity, relating to fossil fuels

ISO 14025:2006

AbioticDepletionPotentialForNonFossilResourcesMineralsAndMetals kg Sb eq

Abiotic depletion potential for non fossil resources minerals and metals:
defines the decreasing availability of non - renewable resources as a result of their extraction and underlaying scarcity, relating to scarce elements and their ores

ISO 14025:2006

GlobalWarmingPotentialBiogenic kg CO2 eq

Global warming potential biogenic:
covers carbon emissions to air (CO2, CO and CH4) originating from the oxidation and/or reduction of aboveground biomass by means of its transformation or degradation (e.g. combustion, digestion, composting, landfilling) and CO2 uptake from the atmosphere through photosynthesis during biomass growth – i.e. corresponding to the carbon content of products, biofuels or above ground plant residues such as litter and dead wood

ISO 14025:2006

GlobalWarmingPotentialFossilFuels kg CO2 eq

Global warming potential fossil fuels:
it covers greenhouse gas (GHG) emissions to any media originating from the oxidation and/or reduction of fossil fuels by means of their transformation or degradation (e.g. combustion, digestion, landfilling, etc.)

ISO 14025:2006

GlobalWarmingPotentialLandUseAndLandUseChange kg CO2 eq

Global warming potential land use and land use change:
factor describing the potential radiative forcing impact of carbon uptakes and emissions (CO2, CO and CH4) originating from carbon stock changes caused by land use change and land use over a given period of time

ISO 14025:2006

GlobalWarmingPotentialTotal kg CO2 eq

Global warming potential total:
it accounts for the total global warming potential arising from fossil, biogenic and land use and land use change emissions

ISO 14025:2006

TroposphericOzoneConcentrationIncrease kg NMVOC eq

Tropospheric ozone concentration increase:
measure of the amoutn of ozone in the troposphere (at the earths surface) where it causes summer smog

ISO 14025:2006

DepletionPotentialOfTheStratosphericOzoneLayer kg CFC11 eq

Depletion potential of the stratospheric ozone layer:
the relative amount of degradation to the ozone layer a product can cause

ISO 14025:2006

AcidificationPotentialAccumulatedExceedance mol H+ eq

Acidification potential accumulated exceedance:
a measure of the acidification caused to land and water from emissions to air of acidifying substances

ISO 14025:2006

EutrophicationPotentialAccumulatedExceedance mol N eq

Eutrophication potential accumulated exceedance:
a measure of the eutrophication caused by emissions

ISO 14025:2006

EutrophicationPotentialFractionOfNutrientsReachingFreshwaterEndCompartment kg (PO4)^(3-) eq

Eutrophication potential fraction of nutrients reaching freshwater end compartment:
a measure of the eutrophication caused by emissions reaching freshwater

ISO 14025:2006

EutrophicationPotentialFractionOfNutrientsReachingMarineEndCompartment kg N eq

Eutrophication potential fraction of nutrients reaching marine end compartment:
a measure of the eutrophication caused by emissions reaching marine water

ISO 14025:2006

WaterDeprivationPotentialDeprivationWeightedWaterConsumption m3

Water deprivation potential deprivation weighted water consumption:
unit for the impact category water use

ISO 14025:2006

NonRenewablePrimaryResourcesUsedAsAnEnergyCarrierFuel MJ

Non renewable primary resources used as an energy carrier fuel:
Materials such as peat, oil, gas, coal, uranium used (first use) as an energy source.

ISO 14025:2006

NonRenewablePrimaryResourcesWithEnergyContentUsedAsMaterial MJ

Non renewable primary resources with energy content used as material:
Primary resources such as oil, gas and coal, used (first use) for products (e.g. plastic-based products).

ISO 14025:2006

NonRenewableSecondaryFuels MJ

Non renewable secondary fuels:
Non-renewable materials with energy content that have crossed the system boundary between product systems and are used as fuel input (energy source) in another product system (e.g. processed solvents, shredded tyres

ISO 14025:2006

RecoveredEnergy MJ

Recovered energy:
energy recovered from disposal of waste in previous systems, such as energy recovery from combustion of landfill gas or energy recovered from other systems using energy sources

ISO 14025:2006

RenewablePrimaryResourcesUsedAsAnEnergyCarrierFuel MJ

Renewable primary resources used as an energy carrier fuel:
Bio-based materials used (first use) as an energy source and hydropower, solar and wind power used in the technosphere are included.

ISO 14025:2006

RenewablePrimaryResourcesWithEnergyContentUsedAsMaterial MJ

Renewable primary resources with energy content used as material:
Bio-based materials used (first use) as materials (e.g. wood, hemp, etc.).

ISO 14025:2006

RenewableSecondaryFuels MJ

Renewable secondary fuels:
renewable materials with energy content that have crossed the system boundary between product systems and are used as fuel input (energy source) in another product system (e.g. biomass residue pellets, chipped waste wood)

ISO 14025:2006

SecondaryMaterials kg

Secondary materials:
material recovered from previous use or from waste which substitutes primary materials

ISO 14025:2006

ConsumptionOfFreshwater m3

Consumption of freshwater:
net freshwater entering the product system being studied that is not returned to the same drainage basin from which it originated

ISO 14025:2006

NetUseOfFreshwater m3

Net use of freshwater:
freshwater entering the product system being studied that is not returned to the same drainage basin from which it originated. Measured using the principles of water footprint inventory analysis according to ISO 14046.

ISO 14025:2006

HazardousWasteDisposed kg

Hazardous waste disposed:
hazardous waste to final repository

ISO 14025:2006

NonHazardousWasteDisposed kg

Non hazardous waste disposed:
Non-hazardous waste is non-toxic and similar to household waste. It consists of inert waste and ordinary household waste

ISO 14025:2006

TotalRadioactiveWasteDisposedMass kg

Total radioactive waste disposed mass:
The sum, in weight, high-, intermediate- and low-level radioactive waste, conditioned, to final repository

ISO 14025:2006

TotalRadioactiveWasteDisposedVolume m3

Total radioactive waste disposed volume:
The sum, in volume, of high-, intermediate- and low-level radioactive waste, conditioned, to final repository

ISO 14025:2006

ComponentsForReUse kg

Components for re use:
Amount of components which are reused at end-of-life

ISO 14025:2006

ExportedElectricalEnergy MJ

Exported electrical energy:
Amount of electrical energy available in the market after incineration

ISO 14025:2006

ExportedThermalEnergy MJ

Exported thermal energy:
Amount of thermal energy available in the market after incineration

ISO 14025:2006

MaterialsForEnergyRecovery kg

Materials for energy recovery:
Secondary fuels for use in the next product system

ISO 14025:2006

MaterialsForRecycling kg

Materials for recycling:
Secondary material for use in the next product system

ISO 14025:2006

LifeCyclePhase IFC Logo FaseDoCicloDeVida No unit

Life cycle phase:
The whole life cycle or only a given phase from which environmental data are valid, ex. A1- A3 (Production stage)

ISO 14025:2006

LifeCycleStagesOmitted No unit

Life cycle stages omitted:
Life cycle stages omitted from the Environmental Product Declaration calculations, ex. B1 - B7 (use stage), C1 - C4 (end of life stage).

ISO 14025:2006

EPDUnit No unit

EPD unit:
The unit of the quantity the environmental indicators values are related with, ex. 1 piece of steel door

ISO 14025:2006

Colour key — where each property comes from (IsSubtypeOf relation):
Own (this template) Inherited from: Master