Product data template, per EN ISO 23387

door

- V1.1

Inactive
Property Unit Description Reference document
Classification<System><Table>Code No unit

Classification<System><Table>code:
Classification code of the product, ex. ClassificationSecclassProductsNumber = Pr_20_85_08

n/a
Classification<System><Table>Title No unit

Classification<System><Table>title:
Classification title of the product, ex. ClassificationSecclassProductsDescription = Timber beams

n/a
Classification<System><Table>Version No unit

Classification<System><Table>version:
Classification system version used, ex. ClassificationSecclassProductsVersion = v1.4

n/a
Name IFC Logo Nome No unit

Name:
The product name shall consist of the following fields: <Source>_<Type>_<Subtype>_<Differentiator_n>, ex. LEDSMART_Luminaire_Interior_1420x37x84mm. For more information, consult the standard draft Building Information Modelling (BIM) - Rules for the Modelling of BIM Objects and the link: https://secclass.pt/wp-content/uploads/2021/10/R_M_ObjectosBIM.pdf

n/a
CommercialName No unit

Commercial name:
The commercial name of the product, which usually is used to define the product for costumers

n/a
ProductType No unit

Product type:
The type of the product

n/a
Description IFC Logo Descricao No unit

Description:
A general description of the object

n/a
EPDRegistrationNumber No unit

EPD registration number:
Registration number of the Environmental Project Declaration document

n/a
ReferenceToOriginalEPD IFC Logo ReferenciaDAP No unit

Reference to original EPD:
a hyperlink to the original EPD according to standard PCR

n/a
DOPReference No unit

DOP reference:
Reference of the Declaration of Performance

n/a
UrlDOP No unit

URL DOP:
A URL to the DoP document (PDF, or digital version)

n/a
SystemManufacturer No unit

System manufacturer:
The System manufacturer of the Doorset systems. Ex. Lock manufacturer

n/a
Manufacturer IFC Logo Fabricante No unit

Manufacturer:
The organization that manufactured and/or assembled the item

n/a
ManufacturerURL No unit

Manufacturer URL:
The website of the organization that manufactured and/or assembled the item

n/a
ManufacturerEmail No unit

Manufacturer email:
The email of the manufacturer

n/a
ManufacturerNumber No unit

Manufacturer number:
The contact number of the manufacturer

n/a
ModelReference IFC Logo ReferenciaModelo No unit

Model reference:
The model number or designator of the product model (or product line) as assigned by the manufacturer of the manufactured item, ex. ASMD Metal Door

n/a
BarCode IFC Logo CodigoDeBarras No unit

Bar code:
The identity of the bar code given to an occurrence of the product

n/a
SerialNumber IFC Logo NumeroDeSerie No unit

Serial number:
The serial number assigned to an occurrence of a product

n/a
GlobalTradeItemNumber IFC Logo NumeroGlobalDeItemComercial No unit

Global trade item number (GTIN):
The Global Trade Item Number (GTIN) is an identifier for trade items developed by GS1 (www.gs1.org), ex. 123456789012

n/a
ProductionDate No unit

Production date:
The date of production of the manufactured item, ex. 31/12/1999 23:59:59

n/a
AcquisitionDate IFC Logo DataAquisicao No unit

Acquisition date:
The date that the manufactured item was purchased, ex. 31/12/1999 23:59:59

n/a
NetWeight IFC Logo PesoLiquido kg

Net weight:
Element net weight excluding shipping packaging, ex. 60 kg

n/a
GrossWeight IFC Logo PesoBruto kg

Gross weight:
Element weight including shipping packaging, ex. 55 kg

n/a
MaterialWeight No unit

Material weight:
Weight of the referenced material in the product. ex. WoodWeight = 20

n/a
<Material>Origin No unit

<Material> origin:
Origin of the referenced material ex. WoodOrigin = Portugal

n/a
<Material>DPPurl No unit

<Material> DPP Url:
The URL that leads to the Digital Product Passport of the selected material

n/a
Packaging<Material>Weight No unit

Packaging <material> weight:
The weight of the packaging material referenced

n/a
ConceptualCost No unit

Conceptual cost:
Conceptual cost estimating is done during the pre-construction stage of a project, ex. 200 EUR

n/a
RecordedActualCost No unit

Recorded actual cost:
the actual cost of the asset , ex. 195EUR

n/a
ReplacementCost No unit

Replacement cost:
An indicative cost for unit replacement, ex. 200 EUR

n/a
FutureCostAssumptions No unit

Future cost assumptions:
Costs estimates for maintaining the element during its lifecycle, ex. 50EUR

n/a
ShippingCost No unit

Shipping cost:
Cost of shipping to installation location

n/a
Constituents No unit

Constituents:
Optional constituent features, parts or finishes, ex. Door with self closing lock

n/a
Color IFC Logo Cor No unit

Color:
Color selection for this object, ex. White, Brown, and Black

n/a
Category No unit

Category:
Category of the product when similar products exist belonging to the same product type. For example ceramic tiles have several categories that can be used in different context. Ex: Floor tile, Skirting, Wall tile, …

n/a
Finish IFC Logo Acabamento No unit

Finish:
Characteristic or primary finish of product

n/a
Features No unit

Features:
Other important characteristics or features relevant to product specification.

n/a
Material No unit

Material:
Characteristic or primary material of product., ex. Pine wood

n/a
FacilityIdentifier No unit

Facility identifier:
A unique identifier assigned to a physical location, such as a manufacturing plant, warehouse, or other facility, where specific activities related to a product occur. It is used to trace operations, ensure compliance, and maintain supply chain transparency.

n/a
EconomicOperatorIdentifier No unit

Economic operator identifier:
A unique identifier assigned to an entity responsible for the product at specific stages of its lifecycle, such as manufacturing, importing, or distribution. It ensures regulatory compliance, accountability, and traceability in the supply chain.

n/a
ManufacturerGLN No unit

Manufacturer GLN:
GLN- Global Location Number of the Manufacturer. This could be your local or headquarter GLN depending on point of origin, ex. 1234567890123

n/a
DataDeliveryCountry No unit

Data delivery country:
Country for which data delivery is planned. Territory (i.e. country, state, region) coded according to ISO 3166-1 Alpha2, ex. FR

n/a
DataDeliveryLanguage No unit

Data delivery language:
Basic language of the data delivery. This element specifies the used languages (acc. ISO 639-1), especially the default language of all language-dependent information, ex. fr

n/a
StartOfValidity No unit

Start of validity:
The start date of validity of the article, ex. 31/12/1999

n/a
EndOfValidity No unit

End of validity:
The end date of validity of the article, ex. 31/12/1999

n/a
<Attachment>Url No unit

<Attachment> Url:
URL to the referenced attachment/digital asset ex. ProductPhotourl = www.manufcaturer.com/product/photo

n/a
DeepLinkUrl No unit

Deep link URL:
A deep link (URL) redirects to a relevant webpage of the supplier or manufacturer company, where further information on the article may be found, ex. www.company.com/product

n/a
CountryOfOrigin No unit

Country of origin:
Country of origin is the country where the article was manufactured, or the last essential processing step was completed. Description of the country according to >>ISO-3166-1 Alpha2<< (Country Subdivision Codes). Country codes must be written in 2 capital letters, ex. PT

n/a
LocationOfOrigin No unit

Location of origin:
The location where the product was manufactured, can be the city or an address

n/a
ProductionProcessSummary No unit

Production process summary:
Stages of production

n/a
TransportType No unit

Transport type:
The type of transport used to distribute the product

n/a
PackagingType No unit

Packaging type:
The type of packaging used for the product

n/a
WaterTightnessRating No unit

Water tightness rating:
Water tightness rating for this object. It is provided according to the national building code. ex. Class 3

EN 1027:2016

DangerousSubstances No unit

Dangerous substances:
Materials used in the product contain or release any dangerious substances as per European or any national standards ex. None

EN14351-1:2006+A2:2016

WindLoadRating No unit

Wind load rating:
Wind load resistance rating for this object. It is provided according to the national building code. ex. Class 5

EN 12210:2016

MechanicalLoadRating No unit

Mechanical load rating:
Mechanical load rating for this object. It is provided according to the national building code. ex. Class 2

EN 12400:2002

AcousticRating IFC Logo ClassificacaoAcustica W/m²K

Acoustic rating:
 It indicates the sound transmission resistance of this object by an index ratio (instead of providing full sound absorption values). ex. 0.5

EN ISO 717-1:2013

ThermalTransmittance IFC Logo TransmitanciaTermica W/m²K

Thermal transmittance:
Thermal transmittance coefficient (U-Value) of an element

EN ISO 10077-1:2017

ThermalTransmittanceSummer IFC Logo TransmitanciaTermicaVerao W/m²K

Thermal transmittance summer:
Summer thermal transmittance coefficient (U-Value) of the glazing only, often referred to as (U-value)

EN ISO 10077-1:2017

ThermalTransmittanceWinter IFC Logo TransmitanciaTermicaeInverno No unit

Thermal transmittance winter:
Winter thermal transmittance coefficient (U-Value) of the glazing only, often referred to as (U-value)

EN ISO 10077-1:2017

RadiationProperties IFC Logo PropriedadesIrradiacao No unit

Radiation properties:
Radiation properties of the product as per relevant standards

EN 13363-1:2003+A1:2007

Infiltration IFC Logo PermeabilidadeAr No unit

Infiltration:
Infiltration flowrate of outside air for the filler object based on the area of the filler object at a pressure level of 50 Pascals. It shall be used, if the length of all joints is unknown. ex. Class 3

EN 12207:2016

FireRating IFC Logo ClassificacaoFogo No unit

Fire rating:
Fire rating for the element. It is given according to the national fire safety classification. ex. Class E

EN 1634-1:2014

SmokeStop IFC Logo EstanquidadeFumo No unit

Smoke stop:
Indication whether the object is designed to provide a smoke stop (TRUE) or not (FALSE). ex. S200

EN 1634-3:2004

AbilityToRelease No unit

Ability to release:
The Breakout facility of the Doorset systems. ex. Released

EN 1125:2008

SelfClosing No unit

Self closing:
The self closing class as per related standards. ex. C 4

EN 1191:2012

DurabilityOfAbilityToRelease No unit

Durability of ability to release:
Durability of the ability to release system ex. release maintained

EN 1155:1997

DurabilityOfSelfClosingAgainstDegradation No unit

Durability of self closing against degradation:
Durability of self closing system against degradation ex. 5

EN 1191:2012

DurabilityOfSelfClosingAgainstAging No unit

Durability of self closing against aging:
Durability of self closing system against aging ex. achieved

EN 1191:2012

HygrothermalRating No unit

Hygrothermal rating:
Resistence against hygrothermal impact from different temperatures and humidities inside and outside. It is given according to the national code or regulation.

ISO 15927-1:2003

SecurityRating No unit

Security rating:
Index based rating system indicating security level. It is given according to the national building code, ex. classification as per BS EN 1630:2011+A1:2015

n/a
VisibleLightReflectance %

Visible light reflectance:
Fraction of the visible light that is reflected by the glazing at normal incidence. ex. 6

ISO 9050:2003

VisibleLightTransmittance %

Visible light transmittance:
Fraction of the visible light that passes the glazing at normal incidence. ex. 90

ISO 9050:2003

SolarAbsorption No unit

Solar absorption:
Proportion of the incident solar radiation that is absorbed by a glazing system. It is the sum of the absorption distributed to the outside and to the inside. Note the following equation: SolarAbsorption + SolarReflectance + SolarTransmittance = 1. e.g. 0.3

ISO 12567-1:2010

SolarReflectance No unit

Solar reflectance:
Proportion of incident solar radiation that is reflected by a glazing system (also called ?e). SolarAbsorption + SolarReflectance + SolarTransmittance = 1. e.g. 0.3

ISO 12567-1:2010

SolarTransmittance No unit

Solar transmittance:
Proportion of incident solar radiation that passes directly through a glazing system. SolarAbsorption + SolarReflectance + SolarTransmittance = 1. e.g. 0.4

ISO 12567-1:2010

SolarHeatGainTransmittance %

Solar heat gain transmittance:
Proportion of the incident solar radiation that contributes to indoor heat gain. It is the solar radiation that passes directly through (SolarTransmittance), plus the part of the absorbed radiation that is distributed to the interior.

ISO 19467-2:2021

ShadingCoefficient No unit

Shading coefficient:
The measure of a glass ability to transmit solar heat, relative to the same ability of a 3 mm (1/8 inch) clear, double-strength, single pane of glass. The shading coefficient is being phased out in favor of the solar heat gain coefficient, whose value multiplied by 1.15 is approximately the Shading Coefficient.

ISO 15099:2003

ForcedEntryResistance No unit

Forced entry resistance:
Classification as per relevant standard

ENV 1627:1999

FireResistantGlass No unit

Fire resistant glass:
Indication whether the glass is fire resistant (TRUE) or not (FALSE)

ISO 9051:1990

BulletResistantGlazingClassification No unit

Bullet resistant glazing classification:
Classification as per standard like ISO 16935:2007

EN 1523:1988

IsExternal IFC Logo EExterno No unit

Is external:
Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building. ex. FALSE

n/a
PanelPosition IFC Logo PosicaoFolha No unit

Panel position:
Position of the panels within the door, so PanelOperation can inform their operation type. The PanelPosition of the door panel has to correspond with the OperationType. Enumerations: LEFT, RIGHT, MIDDLE, NOTDEFINED. PanelPosition should be informed as: <Panel1 position; Panel2 position; ...> Ex. <LEFT; RIGHT>

n/a
PanelOperation IFC Logo TipoDeOperacaoFolha No unit

Panel operation:
It defines the way of operation of the panels, in the order informed in PanelPosition property. The PanelOperation of the door panel has to correspond with the OperationType. Enumerations: SWINGING, DOUBLE_ACTING, SLIDING, FOLDING, REVOLVING, ROLLINGUP, FIXEDPANEL, USERDEFINED, NOTDEFINED. PanelOperation should be informed as: <Panel1 Operation; Panel2 Operation; ...>. Ex. <SLIDING; FIXEDPANEL>

PanelOperation
n/a
HandicapAccessible IFC Logo AcessivelDeficientes No unit

Handicap accessible:
Indication that this object is designed to be accessible by the handicapped. ex. TRUE

n/a
FireExit IFC Logo ESaidaIncendio No unit

Fire exit:
Indication whether this object is designed to serve as an exit in the case of fire (TRUE) or not (FALSE). ex. TRUE

n/a
HasDrive IFC Logo TemAccionamento No unit

Has drive:
Indication whether this object has an automatic drive to operate it (TRUE) or no drive (FALSE) ex. TRUE

n/a
OperationType IFC Logo TipoDeOperacao No unit

Operation type:
Defines the general layout and operation of the door in terms of the partitioning of panels and panel operations. It defines general information that are detailed by PanelPosition and PanelOperation properties. Enumerations: SINGLE_SWING_LEFT, SINGLE_SWING_RIGHT, DOUBLE_DOOR_SINGLE_SWING, DOUBLE_DOOR_SINGLE_SWING_OPPOSITE_LEFT, DOUBLE_DOOR_SINGLE_SWING_OPPOSITE_RIGHT, DOUBLE_SWING_LEFT, DOUBLE_SWING_RIGHT, DOUBLE_DOOR_DOUBLE_SWING, SLIDING_TO_LEFT, SLIDING_TO_RIGHT, DOUBLE_DOOR_SLIDING, FOLDING_TO_RIGHT, FOLDING_TO_LEFT, DOUBLE_DOOR_FOLDING, REVOLVING, ROLLINGUP, SWING_FIXED_LEFT, SWING_FIXED_RIGHT, USERDEFINED, NOTDEFINED. Ex. DOUBLE_DOOR_SINGLE_SWING_OPPOSITE_RIGHT

OperationType
n/a
PredefinedType No unit

Predefined type:
Predefined generic type for the door. Enumerations: DOOR, GATE, TRAPDOOR, USERDEFINED, NOTDEFINED.

n/a
GlazingAreaFraction IFC Logo FraccaoAreaEnvidracada %

Glazing area fraction:
Fraction of the glazing area relative to the total area of the filling element, ex. 0.1

n/a
GlassType No unit

Glass type:
The type of glass used. Ex. Clear, Frosted, Darkened, other

n/a
GlassLayers IFC Logo CamadasVidro No unit

Glass layers:
Number of glass layers within the frame. Ex. 2 for double glazing.

n/a
FillGas IFC Logo GasEnchimento No unit

Fill gas:
Name of the gas by which the gap between two glass layers is filled. ex. Argon

n/a
GlassColor No unit

Glass color:
The color of the glass

n/a
IsTempered IFC Logo ETemperado No unit

Is tempered:
Indication whether the glass is tempered (TRUE) or not (FALSE).

n/a
IsLaminated IFC Logo ELaminado No unit

Is laminated:
Indication whether the glass is layered with other materials (TRUE) or not (FALSE).

n/a
IsCoated IFC Logo ERevestido No unit

Is coated:
Indication whether the glass is coated with a material (TRUE) or not (FALSE).

n/a
IsWired IFC Logo EAramado No unit

Is wired:
Indication whether the glass includes a contained wire mesh to prevent break-in (TRUE) or not (FALSE)

n/a
DoorsetFasteners No unit

Doorset fasteners:
Products such as Carbon steel masonry brackets. ex. frame adjusters with specialised screw fixings for masonry

n/a
DoorsetGlazing No unit

Doorset glazing:
General information about glass panels in the door panel.

n/a
DoorsetSealsOrInsertsFrame No unit

Doorset seals or inserts frame:
Products such as strips and seals for the frame. Ex. Door Sponge Tape

n/a
DoorsetSealsOrInsertsDoor No unit

Doorset seals or inserts door:
Products like strips and seals for doors. Ex. Adhesive Door Sealer

n/a
ThresholdsBaseStrip No unit

Thresholds base strip:
Products such as Floor threshold strips.

n/a
ThresholdsWeatherOrSealStripping No unit

Thresholds weather or seal stripping:
Information about the weather protection of the threshold, such as sealing.

n/a
Hardware No unit

Hardware:
The Hardware of the Doorset systems. ex. Hardware Set (BR-KL-R1)

n/a
SystemAccessories No unit

System accessories:
Products such as Anti-finger trap stiles.

n/a
FillerBetweenFrameAndReveal No unit

Filler between frame and reveal:
Products such as Polyurethane (PUR) expanding foam fillers.

n/a
DoorLeafStructure No unit

Door leaf structure:
The structure of the door leaf ex. Stile, Moulded, Filling, other

n/a
CasingMaterial No unit

Casing material:
Information about the material and finishing of the casing. Ex. Painted wood

n/a
PanelMaterial No unit

Panel material:
The main material composing the door panel, ex. Natural wood

n/a
LiningMaterial No unit

Lining material:
The main material of the door lining, ex. Steel

n/a
ThresholdMaterial No unit

Threshold material:
The main material of the threshold, ex. Granite

n/a
OverPanelMaterial No unit

Over panel material:
The main material of the over panels of the door. Ex. Wood

n/a
SidePanelMaterial No unit

Side panel material:
The main material of the side panels of the door. Ex. Glass

n/a
NominalPanelHeight mm

Nominal panel height:
Height of the door panel, ex. 2050

NominalPanelHeight

EN 951:1998

NominalPanelWidth mm

Nominal panel width:
Width of the door panel, ex. 800

NominalPanelWidth

EN 951:1998

Height mm

Height:
Total outer height of the door lining. It should only be provided, if it is a rectangular door. ex. 2100

Height
n/a
Width mm

Width:
Total outer width of the door lining. It should only be provided, if it is a rectangular door. ex. 1000

Width
n/a
Perimeter mm

Perimeter:
Total perimeter of the outer lining of the door. ex. 6200

Perimeter
n/a
Area m2

Area:
Total area of the outer lining of the door. ex. 2.1

Area
n/a
PanelDepth IFC Logo EspessuraFolha mm

Panel depth:
Depth of the door panel, measured perpendicular to the plane of the door leaf. ex. 50

PanelDepth

EN 951:1998

PanelWidth IFC Logo ProporcaoLarguraFolha No unit

Panel width:
Width of thepanel, given as ratio relative to the total clear opening width of the door. If omited, it defaults to 1, ex. 0.9

PanelWidth
n/a
LiningDepth IFC Logo ProfundidadeAro mm

Lining depth:
Depth of the door lining, measured perpendicular to the plane of the door lining. If omitted (and with a given value to lining thickness) it indicates an adjustable depth (i.e. a depth that adjusts to the thickness of the wall into which the occurrence of this door style is inserted). ex. 300

LiningDepth
n/a
LiningThickness IFC Logo EspessuraAro mm

Lining thickness:
Thickness of the door lining. If LiningThickness value is 0. (zero) it denotes a door without a lining (all other lining parameters shall be set to NIL in this case). If the LiningThickness is NIL it denotes that the value is not available. ex. 20

LiningThickness
n/a
LiningOffset IFC Logo DeslocamentoAroParede mm

Lining offset:
Offset (dimension in plane perpendicular to door leaf) of the door lining. The offset is given as distance between the outer face of the wall to the outer face of the lining. ex. 0

LiningOffset
n/a
LiningToPanelOffsetX IFC Logo DeslocamentoXAroFolha mm

Lining to panel offset X:
Distance between the outer face of the lining to the closest edge of the door panel in the same plane of the door. ex. 30

LiningToPanelOffsetX
n/a
LiningToPanelOffsetY IFC Logo DeslocamentoYAroFolha mm

Lining to panel offset Y:
Distance between the outer face of the wall to the outer face of the door panel perpendicular to the door plane. ex. 270

LiningToPanelOffsetY
n/a
ThresholdDepth IFC Logo ProfundidadeSoleira mm

Threshold depth:
Depth (dimension in plane perpendicular to door leaf) of the door threshold. Only given if the door lining includes a threshold. If omitted (and with a given value to threshold thickness) it indicates an adjustable depth (i.e. a depth that adjusts to the thickness of the wall into which the occurrence of this door style is inserted). ex. 300

ThresholdDepth
n/a
ThresholdThickness IFC Logo EspessuraSoleira mm

Threshold thickness:
Thickness of the door threshold as explained in the figure above. If ThresholdThickness value is 0. (zero) it denotes a door without a threshold (ThresholdDepth shall be set to NIL in this case). If the ThresholdThickness is NIL it denotes that the information about a threshold is not available. ex. 30

ThresholdThickness
n/a
ThresholdOffset IFC Logo DeslocamentoSoleira mm

Threshold offset:
Offset (dimension in plane perpendicular to door leaf) of the door threshold. The offset is given as distance to the outer face of the wall. Only given if the door lining includes a threshold and the parameter is known. ex. 0

ThresholdOffset
n/a
TransomThickness IFC Logo EspessuraPadieiraPorta mm

Transom thickness:
Thickness (width in plane parallel to door leaf) of the transom (if provided - that is, if the TransomOffset attribute is set), which divides the door leaf from a glazing (or window) above. If the TransomThickness is set to zero (and the TransomOffset set to a positive length), then the door is divided vertically into a leaf and transom window area without a physical frame. ex. 400

TransomThickness
n/a
TransomOffset IFC Logo DeslocamentoPadieiraPorta mm

Transom offset:
Offset of the transom (if given) which divides the door leaf from a glazing (or window) above. The offset is given from the bottom of the door opening. ex. 2100

TransomOffset
n/a
OverPanels IFC Logo DimensoesFixosSuperiores No unit

Over panels:
The size of the over panels of the Doorset systems. ex. 400 x 900

OverPanels
n/a
SidePanels IFC Logo DimensoesFixosLaterais No unit

Side panels:
The position and size of the side panels of the Doorset systems. Ex. Left, 40x250; Right, 35x250.

SidePanels
n/a
CasingThickness IFC Logo EspessuraGuarnicao mm

Casing thickness:
Thickness of the casing (dimension in plane of the door leaf). ex. 50

CasingThickness
n/a
CasingDepth IFC Logo ProfundidadeGuarnicao mm

Casing depth:
Depth of the casing (dimension in plane perpendicular to door leaf). ex. 10

CasingDepth
n/a
GlassThickness1 mm

Glass thickness 1:
Thickness of the first (inner) glass layer. ex. 3

n/a
GlassThickness2 mm

Glass thickness 2:
Thickness of the intermediate glass layers. ex. 3

n/a
GlassThickness3 mm

Glass thickness 3:
Thickness of the outer glass layer. ex. 3

n/a
EgressRequirement No unit

Egress requirement:
Openning size requirements for door installation

n/a
NominalHeight IFC Logo AlturaNominal mm

Nominal height:
Typically the vertical or secondary characteristic dimension, ex. 300

n/a
NominalLength IFC Logo ComprimentoNominal mm

Nominal length:
Typically the larger or primary horizontal dimension., ex. 5000

n/a
NominalWidth IFC Logo LarguraNominal mm

Nominal width:
Nominal width of product, typically the characteristic or secondary horizontal or characteristic dimension, ex. 200

n/a
Shape No unit

Shape:
Characteristic shape of product, ex. Rectangle

n/a
WarrantyContent IFC Logo ConteudoGarantia No unit

Warranty content:
A general description of the content of the warranty.

n/a
WarrantyDurationLabor No unit

Warranty duration labor:
Duration of labour warranty., ex. 5 years

n/a
WarrantyDurationParts No unit

Warranty duration parts:
Duration of parts warranty., ex. 5 years

n/a
WarrantyGuarantorLabor No unit

Warranty guarantor labor:
Email address for the organisation responsible for the labour warranty.

n/a
WarrantyGuarantorParts No unit

Warranty guarantor parts:
Email address for the organisation responsible for the parts warranty.

n/a
WarrantyStartDate IFC Logo DataInicioGarantia No unit

Warranty start date:
The date on which the warranty commences, ex. 31/12/1999 23:59:59

n/a
WarrantyIdentifier IFC Logo IdentificadorGarantia No unit

Warranty identifier:
The identifier assigned to a warranty

n/a
WarrantyEndDate No unit

Warranty end date:
The date on which the warranty expires, ex. 31/12/1999 23:59:59

n/a
IsExtendedWarranty IFC Logo GarantiaEAlargada No unit

Is extended warranty:
Indication of whether this is an extended warranty whose duration is greater than that normally assigned to an artefact (=TRUE) or not (= FALSE), ex. FALSE

n/a
Exclusions IFC Logo ExclusoesGarantia No unit

Exclusions:
Items, conditions or actions that may be excluded from the warranty or that may cause the warranty to become void

n/a
InstallationDate IFC Logo DataInstalacao No unit

Installation date:
The date that the manufactured item was installed (per instance), ex. 31/12/1999 23:59:59

n/a
InstallationLocation No unit

Installation location:
The location where the product is installed

n/a
EnvironmentalCertification IFC Logo CertificacaoAmbiental No unit

Environmental certification:
Environmental certifications aquired for the product ex. PEFC, FSC, MTCC, None, Other

n/a
IsReusable No unit

Is reusable:
Indication of whether this product is reusable (=TRUE) or not (= FALSE)

n/a
IsRemanufacturable No unit

Is remanufacturable:
Indication of whether this product is remanufacturable (=TRUE) or not (= FALSE)

n/a
IsUpgradable No unit

Is upgradable:
Indication of whether this product is upgradable (=TRUE) or not (= FALSE)

n/a
IsRepairable No unit

Is repairable:
Indication of whether this product is repairable (=TRUE) or not (= FALSE)

n/a
WasteGenerated No unit

Waste generated:
List of waste generated by the product, including packaging

n/a
ContaminatingWaste No unit

Contaminating waste:
Identify potentially contaminating waste/substances

n/a
DismantlingMethod No unit

Dismantling method:
Appropriate dismantling method for each waste (recycling, reuse, repair, resale, restoration, reincorporation, improvement)

n/a
REACHLabel No unit

Reach label:
Indication as to whether an article or ingredient of an article is subject to the REACH Regulation: articles and ingredients of articles that are listed as substances of very high concern under REACH have to be labelled in the data delivery. Allowed values: yes / no / no data. If REACH is not applicable e.g. services use (no). If REACH info is not available, use (no data).

n/a
REACHListDate No unit

Reach list date:
Date, on which the product was checked by the manufacturer for REACH.

n/a
SustainabilityPerformance No unit

Sustainability performance:
Description of the sustainability issue(s) which the object satisfies

n/a
IsItemNew No unit

Is item new:
Indication of whether this item is new (=TRUE) or not (= FALSE)

n/a
IsItemPartiallyRecycled No unit

Is item partially recycled:
Indication of whether this item is partially recycled (=TRUE) or not (= FALSE)

n/a
IsItemRecycled No unit

Is item recycled:
Indication of whether this item is totally recycled (=TRUE) or not (= FALSE)

n/a
ExpectedServiceLife No unit

Expected service life:
Expected service life in years, ex. 60 years

n/a
FunctionalUnitReference No unit

Functional unit reference:
Reference to a database or a classification, ex. EPD international

n/a
DangerousSubstances No unit

Dangerous substances:
Materials used in the product contain or release any dangerous substances as per European or any national standards ex. None

n/a
InertWaste IFC Logo ResiduosInertes kg

Inert waste:
Quantity of inert waste generated

n/a
AbioticDepletionPotentialForFossilResources MJ

Abiotic depletion potential for fossil resources:
defines the decreasing availability of non - renewable resources as a result of their extraction and underlaying scarcity, relating to fossil fuels

ISO 14025:2006

AbioticDepletionPotentialForNonFossilResourcesMineralsAndMetals kg Sb eq

Abiotic depletion potential for non fossil resources minerals and metals:
defines the decreasing availability of non - renewable resources as a result of their extraction and underlaying scarcity, relating to scarce elements and their ores

ISO 14025:2006

GlobalWarmingPotentialBiogenic kg CO2 eq

Global warming potential biogenic:
covers carbon emissions to air (CO2, CO and CH4) originating from the oxidation and/or reduction of aboveground biomass by means of its transformation or degradation (e.g. combustion, digestion, composting, landfilling) and CO2 uptake from the atmosphere through photosynthesis during biomass growth – i.e. corresponding to the carbon content of products, biofuels or above ground plant residues such as litter and dead wood

ISO 14025:2006

GlobalWarmingPotentialFossilFuels kg CO2 eq

Global warming potential fossil fuels:
it covers greenhouse gas (GHG) emissions to any media originating from the oxidation and/or reduction of fossil fuels by means of their transformation or degradation (e.g. combustion, digestion, landfilling, etc.)

ISO 14025:2006

GlobalWarmingPotentialLandUseAndLandUseChange kg CO2 eq

Global warming potential land use and land use change:
factor describing the potential radiative forcing impact of carbon uptakes and emissions (CO2, CO and CH4) originating from carbon stock changes caused by land use change and land use over a given period of time

ISO 14025:2006

GlobalWarmingPotentialTotal kg CO2 eq

Global warming potential total:
it accounts for the total global warming potential arising from fossil, biogenic and land use and land use change emissions

ISO 14025:2006

TroposphericOzoneConcentrationIncrease kg NMVOC eq

Tropospheric ozone concentration increase:
measure of the amoutn of ozone in the troposphere (at the earths surface) where it causes summer smog

ISO 14025:2006

DepletionPotentialOfTheStratosphericOzoneLayer kg CFC11 eq

Depletion potential of the stratospheric ozone layer:
the relative amount of degradation to the ozone layer a product can cause

ISO 14025:2006

AcidificationPotentialAccumulatedExceedance mol H+ eq

Acidification potential accumulated exceedance:
a measure of the acidification caused to land and water from emissions to air of acidifying substances

ISO 14025:2006

EutrophicationPotentialAccumulatedExceedance mol N eq

Eutrophication potential accumulated exceedance:
a measure of the eutrophication caused by emissions

ISO 14025:2006

EutrophicationPotentialFractionOfNutrientsReachingFreshwaterEndCompartment kg (PO4)^(3-) eq

Eutrophication potential fraction of nutrients reaching freshwater end compartment:
a measure of the eutrophication caused by emissions reaching freshwater

ISO 14025:2006

EutrophicationPotentialFractionOfNutrientsReachingMarineEndCompartment kg N eq

Eutrophication potential fraction of nutrients reaching marine end compartment:
a measure of the eutrophication caused by emissions reaching marine water

ISO 14025:2006

WaterDeprivationPotentialDeprivationWeightedWaterConsumption m3

Water deprivation potential deprivation weighted water consumption:
unit for the impact category water use

ISO 14025:2006

NonRenewablePrimaryResourcesUsedAsAnEnergyCarrierFuel MJ

Non renewable primary resources used as an energy carrier fuel:
Materials such as peat, oil, gas, coal, uranium used (first use) as an energy source.

ISO 14025:2006

NonRenewablePrimaryResourcesWithEnergyContentUsedAsMaterial MJ

Non renewable primary resources with energy content used as material:
Primary resources such as oil, gas and coal, used (first use) for products (e.g. plastic-based products).

ISO 14025:2006

NonRenewableSecondaryFuels MJ

Non renewable secondary fuels:
Non-renewable materials with energy content that have crossed the system boundary between product systems and are used as fuel input (energy source) in another product system (e.g. processed solvents, shredded tyres

ISO 14025:2006

RecoveredEnergy MJ

Recovered energy:
energy recovered from disposal of waste in previous systems, such as energy recovery from combustion of landfill gas or energy recovered from other systems using energy sources

ISO 14025:2006

RenewablePrimaryResourcesUsedAsAnEnergyCarrierFuel MJ

Renewable primary resources used as an energy carrier fuel:
Bio-based materials used (first use) as an energy source and hydropower, solar and wind power used in the technosphere are included.

ISO 14025:2006

RenewablePrimaryResourcesWithEnergyContentUsedAsMaterial MJ

Renewable primary resources with energy content used as material:
Bio-based materials used (first use) as materials (e.g. wood, hemp, etc.).

ISO 14025:2006

RenewableSecondaryFuels MJ

Renewable secondary fuels:
renewable materials with energy content that have crossed the system boundary between product systems and are used as fuel input (energy source) in another product system (e.g. biomass residue pellets, chipped waste wood)

ISO 14025:2006

SecondaryMaterials kg

Secondary materials:
material recovered from previous use or from waste which substitutes primary materials

ISO 14025:2006

ConsumptionOfFreshwater m3

Consumption of freshwater:
net freshwater entering the product system being studied that is not returned to the same drainage basin from which it originated

ISO 14025:2006

NetUseOfFreshwater m3

Net use of freshwater:
freshwater entering the product system being studied that is not returned to the same drainage basin from which it originated. Measured using the principles of water footprint inventory analysis according to ISO 14046.

ISO 14025:2006

HazardousWasteDisposed kg

Hazardous waste disposed:
hazardous waste to final repository

ISO 14025:2006

NonHazardousWasteDisposed kg

Non hazardous waste disposed:
Non-hazardous waste is non-toxic and similar to household waste. It consists of inert waste and ordinary household waste

ISO 14025:2006

TotalRadioactiveWasteDisposedMass kg

Total radioactive waste disposed mass:
The sum, in weight, high-, intermediate- and low-level radioactive waste, conditioned, to final repository

ISO 14025:2006

TotalRadioactiveWasteDisposedVolume m3

Total radioactive waste disposed volume:
The sum, in volume, of high-, intermediate- and low-level radioactive waste, conditioned, to final repository

ISO 14025:2006

ComponentsForReUse kg

Components for re use:
Amount of components which are reused at end-of-life

ISO 14025:2006

ExportedElectricalEnergy MJ

Exported electrical energy:
Amount of electrical energy available in the market after incineration

ISO 14025:2006

ExportedThermalEnergy MJ

Exported thermal energy:
Amount of thermal energy available in the market after incineration

ISO 14025:2006

MaterialsForEnergyRecovery kg

Materials for energy recovery:
Secondary fuels for use in the next product system

ISO 14025:2006

MaterialsForRecycling kg

Materials for recycling:
Secondary material for use in the next product system

ISO 14025:2006

LifeCyclePhase IFC Logo FaseDoCicloDeVida No unit

Life cycle phase:
The whole life cycle or only a given phase from which environmental data are valid, ex. A1- A3 (Production stage)

ISO 14025:2006

LifeCycleStagesOmitted No unit

Life cycle stages omitted:
Life cycle stages omitted from the Environmental Product Declaration calculations, ex. B1 - B7 (use stage), C1 - C4 (end of life stage).

ISO 14025:2006

EPDUnit No unit

EPD unit:
The unit of the quantity the environmental indicators values are related with, ex. 1 piece of steel door

ISO 14025:2006

Colour key — where each property comes from (IsSubtypeOf relation):
Own (this template) Inherited from: Master