EN 1155:1997
Atributos do documento de referência:
GUID | 333dffb01c58478e9747b897e616a44d |
---|---|
Nome | EN 1155:1997 |
Título | Building hardware. Electrically powered hold-open devices for swing doors. Requirements and test methods |
Descrição | This European Standard specifies requirements for separate hold-open devices and also for hold-open mechanisms incorporated in a door closer. Electrically powered hold-open devices for swing doors manufactured according to this European Standard can hold a swing door at a fixed position or can allow the door to swing freely. In each case interruption of the electrical supply will cause the controlled door to close positively. Electrically powered hold-open devices manufactured in accordance with this European Standard are recommended for use wherever there is a requirement for reliable hold-open and release of self closing fire/smoke door assemblies. Whilst these devices can incorporate smoke or fire detection elements, the performance of those particular elements is outside of the scope of this European Standard. NOTE : The series of European Standards EN 54 covers the requirements, test methods and performance criteria of resettable smoke/fire detectors. |
Estado | published |
Propriedades que utilizam este documento de referência:
Modelo de dados | Propriedade |
---|---|
Porta V1.1.1 | DurabilidadeCapacidadeDesbloqueio |
Porta V1.2.1 | DurabilidadeCapacidadeDesbloqueio |